{"product_id":"ics-triplex-t8153c-trusted-communication-interface-adapter","title":"ICS Triplex T8153C Trusted Communication Interface Adapter","description":"\u003ch2\u003eICS Triplex T8153C Trusted Communication Interface Adapter\u003c\/h2\u003e\n\u003cp\u003eConfigured for communication interface expansion in the Trusted TMR control system, the \u003cstrong\u003eICS Triplex T8153C\u003c\/strong\u003e (\u003cstrong\u003eT8153\u003c\/strong\u003e Trusted Communication Interface Adapter) provides direct physical and electrical execution. The adapter mounts to the rear of the Trusted Communication Interface Module inside the Trusted Controller Chassis and transfers Ethernet and serial communication channels to external equipment. It supports multiple communication interfaces while minimizing additional field wiring between the controller and connected devices.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies \u003cstrong\u003eT8153C\u003c\/strong\u003e as a single catalog model. No official suffix definition or hardware variant matrix is provided; therefore, no suffix interpretation is included.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT8153C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTrusted Communication Interface Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipment Origin\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.5 x 10.7 x 2.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100BaseT Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Data Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e4 x RS422\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull RS232 Interface\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternative Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10 % to 95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003eRear-mounted to Trusted Communication Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eThe T8153C is designed for operation within the ICS Triplex Trusted TMR platform. Consequently, it supports communication paths required by a \u003cstrong\u003etriple modular redundancy (TMR) 2oo3 architecture\u003c\/strong\u003e. The adapter provides the physical communication interfaces, while the associated Trusted Communication Interface Module performs protocol processing. Furthermore, the rear-mounted arrangement reduces external interconnecting cables and maintains the chassis communication layout. The module installation also supports system maintenance without introducing separate communication interface assemblies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the T8153C perform communication protocol processing?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The T8153C functions as a communication interface adapter. Protocol processing is performed by the associated Trusted Communication Interface Module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the Ethernet and serial ports operate simultaneously?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The adapter provides dedicated physical interfaces for Ethernet, RS422\/485, and RS232 communication. Actual simultaneous operation depends on the configuration supported by the installed Communication Interface Module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the T8153C intended for standalone operation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The adapter is designed to mount directly onto the Trusted Communication Interface Module within the Trusted Controller Chassis and does not operate as an independent communication device.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the controller chassis power is isolated before installing or removing the adapter.\u003c\/li\u003e\n\u003cli\u003eMount the adapter directly onto the rear connector of the compatible Trusted Communication Interface Module and confirm complete connector engagement.\u003c\/li\u003e\n\u003cli\u003eRoute Ethernet and serial communication cables separately from high-voltage power wiring to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the control cabinet grounding practice and avoid multiple shield termination points unless specified by the system design.\u003c\/li\u003e\n\u003cli\u003eConfirm connector retention before energizing the controller and inspect communication status after commissioning.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around communication cables to prevent excessive bending or mechanical stress on the rear connectors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":44512014893144,"sku":"T8153","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/T8153-3_1200x1200_f32342e9-b660-4d00-b818-ebb53f4c7aae.jpg?v=1786095978","url":"https:\/\/www.industriaxplc.com\/id\/products\/ics-triplex-t8153c-trusted-communication-interface-adapter","provider":"IndustriaX Limited","version":"1.0","type":"link"}