{"product_id":"ics-triplex-t7310-i-o-transceiver-module","title":"ICS Triplex T7310 I\/O Transceiver Module","description":"\u003ch2\u003eICS Triplex T7310 I\/O Transceiver Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for triplicated I\/O Safetybus communication in the ICS Triplex Trusted TMR system, the \u003cstrong\u003eICS Triplex T7310\u003c\/strong\u003e (\u003cstrong\u003eT7310\u003c\/strong\u003e I\/O Transceiver Module) provides the physical communication path between one processor channel and its assigned I\/O chassis. It receives processor commands, validates the chassis identification, transfers commands through the Safetybus backplane, buffers I\/O responses, and returns data to the corresponding processor.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT7310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Transceiver Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eTrusted TMR Safety System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Function\u003c\/td\u003e\n\u003ctd\u003eI\/O Safetybus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Configuration\u003c\/td\u003e\n\u003ctd\u003eThree T7310 modules per I\/O chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Interface\u003c\/td\u003e\n\u003ctd\u003eOne processor channel per T7310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Address Validation\u003c\/td\u003e\n\u003ctd\u003ePhysical chassis identification switch comparison\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003eSafetybus backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Interface\u003c\/td\u003e\n\u003ctd\u003eI\/O Safetybus cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEstimated shipping size: 3.2 x 26.3 x 32.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e8 W, 27 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e10 to 55 Hz, +\/- 0.15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTMR Safetybus Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eThe T7310 operates as one channel of a three-module I\/O transceiver set. Each module communicates with only one processor module, which maintains independent communication paths across the TMR architecture.\u003c\/p\u003e\n\u003cp\u003eThe module reads the I\/O chassis identification code from incoming Safetybus commands. It then compares the received address with the physical chassis identification switch setting. Therefore, only commands addressed to the local chassis proceed through the backplane Safetybus to the designated I\/O modules.\u003c\/p\u003e\n\u003cp\u003eFor return communication, the T7310 buffers response data from the I\/O modules. It then transfers the data through the chassis backplane and I\/O Safetybus cable to the associated processor channel. This arrangement maintains channel separation within the TMR communication structure.\u003c\/p\u003e\n\u003ch3\u003eTMR and Fail-Safe Communication Behavior\u003c\/h3\u003e\n\u003cp\u003eThe Trusted architecture uses triple modular redundancy to maintain independent processor-to-I\/O communication channels. The T7310 participates in this architecture by assigning each transceiver to a single processor channel rather than combining the three communication paths.\u003c\/p\u003e\n\u003cp\u003eThe available data confirms TMR operation and independent communication paths. However, the supplied specifications do not define a specific SIL certification level, galvanic isolation rating, or numerical communication latency for the T7310. These values should therefore be verified against the applicable ICS Triplex Trusted system manual before system qualification.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many T7310 modules are installed in one I\/O chassis?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied technical description specifies three T7310 modules operating as a triplicated redundant set.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does each T7310 communicate with all three processor modules?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each T7310 communicates exclusively with one processor module and maintains its corresponding communication path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the T7310 prevent commands from reaching the wrong I\/O chassis?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module compares the chassis identification code in incoming commands with the physical chassis identification switch setting before directing valid commands onto the backplane Safetybus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the T7310 in the designated Trusted I\/O chassis position and follow the chassis manufacturer's mechanical installation procedure.\u003c\/p\u003e\n\u003cp\u003eConnect the I\/O Safetybus cabling according to the system wiring documentation. Keep Safetybus communication cables separated from high-voltage power conductors and high-current switching circuits to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eVerify the physical chassis identification switch before commissioning. The configured identification must correspond with the chassis address expected by the processor communication system.\u003c\/p\u003e\n\u003cp\u003eEnsure that the module remains within the specified 0 deg C to 60 deg C operating temperature range and 0 to 95% RH non-condensing humidity range. Maintain adequate chassis ventilation because the module dissipates approximately 8 W during operation.\u003c\/p\u003e\n\u003cp\u003eBefore energization, inspect the backplane connector and cable interfaces for contamination, mechanical damage, or incorrect seating. For TMR installations, verify the three independent T7310 channel positions and their associated processor and Safetybus connections against the approved system configuration.\u003c\/p\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":44547569123416,"sku":"T7310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/T7310-3_1200x1200_300d89ca-ed6a-460d-ac12-74668309706e.jpg?v=1786350627","url":"https:\/\/www.industriaxplc.com\/id\/products\/ics-triplex-t7310-i-o-transceiver-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}