{"product_id":"honeywell-tc-tcnh-controlnet-interface-module","title":"Honeywell TC-TCNH ControlNet Interface Module","description":"\u003ch2\u003eHoneywell TC-TCNH ControlNet Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-TCNH\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-TCNH\u003c\/strong\u003e ControlNet Interface Module, operates as a dedicated hardware component for deterministic ControlNet communication between Experion PKS controller chassis and distributed I\/O network devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-TCNH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eControlNet Interface Module \/ Network Bridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible System\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS C200\/C300 Controller Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Data Rate\u003c\/td\u003e\n\u003ctd\u003e5 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eTrunk line \/ Drop line with redundant media support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC connectors, Channel A and Channel B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 850 mA at 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 4.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle chassis slot module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHART and Process Network Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell TC-TCNH performs ControlNet network interface functions within the Experion PKS control architecture. The module transfers controller data and I\/O communication packets through deterministic scheduling mechanisms defined by the ControlNet protocol.\u003c\/p\u003e\n\u003cp\u003eThe module supports redundant ControlNet media through dual communication channels. Channel separation allows network availability configurations where two physical communication paths are installed between connected nodes.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell process control environments, network modules within the Experion PKS platform maintain communication consistency with field-level devices and controller resources. Process signal interfaces such as 4-20 mA HART loop protocol, FOUNDATION Fieldbus, or Profibus PA connectivity are handled through dedicated field interface modules rather than the TC-TCNH itself.\u003c\/p\u003e\n\u003cp\u003eChannel-to-channel isolation and controlled network communication timing depend on the complete chassis configuration and connected I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TC-TCNH support redundant ControlNet communication paths?\u003cbr\u003eA: Yes. The module provides dual ControlNet channels for redundant media configurations. Network redundancy depends on the installed cable infrastructure and connected ControlNet devices.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TC-TCNH be installed in any Experion PKS chassis slot?\u003cbr\u003eA: The module uses a standard single-slot chassis position. Slot compatibility depends on the specific Experion PKS controller chassis configuration.\u003c\/p\u003e\n\u003cp\u003eQ: What power load does the TC-TCNH place on the chassis backplane?\u003cbr\u003eA: The module requires approximately 850 mA at 5.1 VDC with a maximum power dissipation of 4.4 W.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the TC-TCNH module in the designated Experion PKS controller chassis slot according to the system hardware configuration manual.\u003c\/li\u003e\n\u003cli\u003eVerify chassis power removal before module insertion or removal unless the installed system configuration specifically supports hot-swap operation.\u003c\/li\u003e\n\u003cli\u003eUse approved ControlNet coaxial cabling with correct BNC termination practices.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing separation between communication wiring and high-voltage power conductors.\u003c\/li\u003e\n\u003cli\u003eConnect redundant ControlNet channels according to the network redundancy design requirements.\u003c\/li\u003e\n\u003cli\u003eVerify grounding and shield termination practices to minimize communication interference.\u003c\/li\u003e\n\u003cli\u003eConfirm module status indicators and network diagnostics after installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44357128290392,"sku":"TC-TCNH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-TCNH-2.jpg?v=1783671069","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-tc-tcnh-controlnet-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}