{"product_id":"honeywell-tc-oav081-analog-output-module","title":"Honeywell TC-OAV081 Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell TC-OAV081 is a high-performance analog output module designed for precision control signal generation within industrial automation environments. As part of the Honeywell control system architecture, this module provides 8 independent channels capable of operating in both voltage and current modes. It is engineered to interface seamlessly with actuators, control valves, and variable frequency drives, making it a critical component for process control in sectors such as power generation, oil and gas refining, and chemical manufacturing. The module ensures high-resolution output and calibrated accuracy, which are essential for maintaining stable process loops and minimizing variability.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 independent analog output channels.\u003c\/li\u003e\n\u003cli\u003eSupports both voltage (-10.4 V to +10.4 V) and current (0 to 21 mA) output modes.\u003c\/li\u003e\n\u003cli\u003eHigh-resolution output: 320 uV per count for voltage and 650 nA per count for current.\u003c\/li\u003e\n\u003cli\u003eIntegrated electronic protection against overvoltage (up to 24 VAC\/VDC) and short circuits.\u003c\/li\u003e\n\u003cli\u003eFast update rate of 25 ms for all channels and settling time of less than 2 ms.\u003c\/li\u003e\n\u003cli\u003eRobust noise immunity with minimal RFI deviation.\u003c\/li\u003e\n\u003cli\u003eHigh drive capability supporting loads up to 2000 ohm (voltage) and 750 ohm (current).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe TC-OAV081 is widely utilized in distributed control systems (DCS) for regulating critical process variables. Typical applications include the positioning of pneumatic or electric control valves, speed control for industrial motors via drives, and providing setpoints for auxiliary control equipment in heavy industrial plants.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-OAV081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Range\u003c\/td\u003e\n\u003ctd\u003e-10.4 V to +10.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Range\u003c\/td\u003e\n\u003ctd\u003e0 to 21 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Resolution\u003c\/td\u003e\n\u003ctd\u003e320 uV per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Resolution\u003c\/td\u003e\n\u003ctd\u003e650 nA per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003eBetter than 0.05 percent of range at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003e24 VAC or VDC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Update Rate\u003c\/td\u003e\n\u003ctd\u003e25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Settling Time\u003c\/td\u003e\n\u003ctd\u003eLess than 2 ms to 95 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2550 VDC (1 s, user to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.9 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before inserting or removing the module from the I\/O rack.\u003c\/li\u003e\n\u003cli\u003eUse the specified TC-TBNH 20-position terminal blocks for secure field wiring.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices to ensure the integrity of the analog signals and to protect against EMI\/RFI.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables away from high-voltage power lines to prevent induced noise.\u003c\/li\u003e\n\u003cli\u003eVerify that the load impedance on each channel is within the specified limits (0-750 ohm for current, \u0026gt;2000 ohm for voltage) to prevent output saturation or errors.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe procedures to prevent damage to internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the TC-OAV081?\u003c\/h3\u003e\u003cp\u003eThe TC-OAV081 is an analog output module used to convert digital control signals from the processor into precise analog voltage or current signals to drive field devices like valves and actuators.\u003c\/p\u003e\u003ch3\u003eCan this module be used for both voltage and current signals?\u003c\/h3\u003e\u003cp\u003eYes, the module is designed to support both modes, allowing for flexible configuration based on the requirements of the connected field instrument.\u003c\/p\u003e\u003ch3\u003eWhat is the required terminal block for this module?\u003c\/h3\u003e\u003cp\u003eThe module is designed to be used with the TC-TBNH 20-position terminal block.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44683780882520,"sku":"TC-OAV081","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_494e9057-cfac-4fcd-acab-d06e53c3b7c6.jpg?v=1788114046","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-tc-oav081-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}