{"product_id":"honeywell-tc-oah061-analog-output-module-副本","title":"TC-IOLI01 Input Module | Honeywell","description":"\u003ch2\u003eHoneywell TC-IOLI01 Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for digital field input acquisition in Honeywell I\/O subsystem architectures, the \u003cstrong\u003eHoneywell TC-IOLI01 51403427-125\u003c\/strong\u003e (\u003cstrong\u003eTC-IOLI01\u003c\/strong\u003e input module) provides direct electrical interface execution between 24 VDC control power and mixed digital input circuitry within distributed control backplane environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo structured manufacturer-defined suffix decomposition is provided for the identifier “51403427-125”. The module is treated as a single-order assembly level identifier associated with the TC-IOLI01 hardware type. No additional functional segmentation is inferred.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-IOLI01 51403427-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7 x 14 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eapprox 6 W (24 VDC x 250 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/- 10 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e250 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eDigital input \/ mixed AC-DC interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Reference\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 50\/60 Hz (as declared interface rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e+\/- 4 kV line to ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Electrical Isolation and Input Conditioning (Honeywell I\/O Architecture Context)\u003c\/h3\u003e\n\u003cp\u003eWithin Honeywell distributed control I\/O implementations, input modules of this class typically implement galvanic separation between field wiring and backplane logic domains. The 1500 VAC isolation barrier defines the separation boundary for noise rejection and fault containment. Surge suppression at +\/- 4 kV line-to-ground is implemented at the front-end interface stage to mitigate transient overvoltage coupling from field wiring induced switching events.\u003c\/p\u003e\n\u003cp\u003eThe 24 VDC supply domain is internally regulated for input conditioning circuits, while discrete input detection thresholds are mapped against defined voltage\/current windows depending on AC or DC field signal presence. Mixed input labeling (120 VAC \/ 24 VDC \/ 13 mA reference) indicates configurable or multi-standard sensing front-end compatibility rather than a single fixed excitation topology.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swap insertion under live backplane conditions?\u003cbr\u003eA: Hot-swap capability is dependent on system rack implementation. Electrically, backplane sequencing must ensure field input lines are de-energized or current-limited prior to insertion to prevent inrush into input protection stages.\u003c\/p\u003e\n\u003cp\u003eQ: What is the impact of backplane load on 24 VDC consumption stability?\u003cbr\u003eA: The module draws approximately 250 mA at 24 VDC. Voltage droop sensitivity is governed by rack power distribution impedance and upstream DC supply regulation tolerance.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 1500 VAC isolation rating continuous or dielectric withstand only?\u003cbr\u003eA: The 1500 VAC specification represents dielectric withstand capability under test conditions and is not a continuous operating voltage rating.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module shall be installed on a grounded DIN or proprietary Honeywell I\/O rack backplane with verified earth bonding continuity below 1 ohm where applicable system standards require it. Field wiring must maintain separation between AC and DC input conductors to minimize capacitive coupling. Shielded cables, where used, shall have single-point grounding at the cabinet entry side to prevent ground loop formation. Torque specifications for terminal blocks shall follow manufacturer rack hardware documentation. Wiring routes shall avoid parallel runs with high-current switching conductors such as motor drives or contactor coils.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44296188362840,"sku":"TC-IOLI01 51403427-125","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-IOLI0151403427-125-3.jpg?v=1782809512","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-tc-oah061-analog-output-module-%e5%89%af%e6%9c%ac","provider":"IndustriaX Limited","version":"1.0","type":"link"}