{"product_id":"honeywell-tc-iah061-experion-analog-input-module","title":"Honeywell TC-IAH061 Experion Analog Input Module","description":"\u003ch2\u003eHoneywell TC-IAH061 Experion Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for isolated analog signal acquisition in Honeywell Experion control systems, the \u003cstrong\u003eHoneywell TC-IAH061\u003c\/strong\u003e (\u003cstrong\u003eTC-IAH061\u003c\/strong\u003e Experion Analog Input Module) provides direct physical and electrical execution for 6-channel field input monitoring with galvanically isolated measurement circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-IAH061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExperion Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.52kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.3 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e6 galvanically isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog input signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Circuit Detection\u003c\/td\u003e\n\u003ctd\u003eUpscale reading for voltage input; zero scale reading for current input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical OC Detection Time\u003c\/td\u003e\n\u003ctd\u003e5 seconds for voltage; 1 second for current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bandwidth\u003c\/td\u003e\n\u003ctd\u003e0 to 15 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFI Immunity\u003c\/td\u003e\n\u003ctd\u003eError less than 2.0% of range at 10 V\/m, 27 to 1000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Update Rate\u003c\/td\u003e\n\u003ctd\u003e25 ms for all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Terminal Block\u003c\/td\u003e\n\u003ctd\u003eTC_TBNH 20-position terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Signal Isolation and DCS Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TC-IAH061 is designed for analog measurement integration within Honeywell Experion architectures. The module provides galvanically isolated input channels to separate field wiring circuits from internal system electronics.\u003c\/p\u003e\n\u003cp\u003eMoreover, the isolated channel design supports process instrumentation connections where electrical separation is required between individual field signals and the control system interface. The module architecture supports standard DCS analog acquisition requirements, including signal integrity control and channel-to-channel isolation.\u003c\/p\u003e\n\u003cp\u003eThe module supports analog loop monitoring functions with defined open-circuit detection behavior. Voltage input failures generate upscale readings, while current input failures generate zero scale readings for diagnostic processing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many analog input channels does the TC-IAH061 provide?\u003cbr\u003eA: The TC-IAH061 provides 6 galvanically isolated analog input channels.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module detect open circuit conditions?\u003cbr\u003eA: The module applies upscale detection for voltage inputs and zero scale detection for current inputs.\u003c\/p\u003e\n\u003cp\u003eQ: What terminal block is compatible with the TC-IAH061 module?\u003cbr\u003eA: The module connects through the Honeywell TC_TBNH 20-position terminal block.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the TC-IAH061 according to the Honeywell Experion I\/O system hardware configuration requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify terminal block wiring before applying field power to prevent incorrect signal connections.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-voltage power cables to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the plant grounding standard and avoid multiple uncontrolled grounding points.\u003c\/li\u003e\n\u003cli\u003eConfirm field loop polarity and signal type before commissioning the input channels.\u003c\/li\u003e\n\u003cli\u003eCheck module seating and backplane connection integrity during rack installation.\u003c\/li\u003e\n\u003cli\u003eValidate analog input values and open-circuit detection behavior during system testing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44349955932248,"sku":"TC-IAH061 96978074-A01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-IAH06196978074-A01-3.jpg?v=1783584995","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-tc-iah061-experion-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}