{"product_id":"honeywell-mu-gaih13-galvanically-isolated-high-level-analog-input-fta","title":"Honeywell MU-GAIH13 Galvanically Isolated High-Level Analog Input FTA","description":"\u003ch2\u003eHoneywell MU-GAIH13 Galvanically Isolated High-Level Analog Input FTA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MU-GAIH13-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU-GAIH13\u003c\/strong\u003e Galvanically Isolated High-Level Analog Input FTA, operates as a dedicated hardware component for analog signal isolation and transmitter interface processing within Honeywell TDC 3000, HPM, and Experion PKS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-GAIH13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51304718-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eGalvanically Isolated High-Level Analog Input Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000, HPM, Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 1-5 VDC, 0-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Interface\u003c\/td\u003e\n\u003ctd\u003eCompression Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTA Size\u003c\/td\u003e\n\u003ctd\u003eSize B, approximately 307 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field circuits and system electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Support\u003c\/td\u003e\n\u003ctd\u003e2-wire and 3-wire analog transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal coating for industrial environmental protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop and Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MU-GAIH13 provides isolated analog signal termination for process transmitters connected to Honeywell control systems. Therefore, the module maintains electrical separation between field wiring and internal I\/O processing circuits.\u003c\/p\u003e\n\u003cp\u003eThe FTA supports standard process analog inputs including 4-20 mA DC current loops and voltage input ranges. In addition, the galvanic isolation design reduces signal disturbance caused by ground potential differences, field noise, and transient electrical conditions.\u003c\/p\u003e\n\u003cp\u003eThe module architecture aligns with Honeywell process control requirements for channel-to-channel isolation and protected analog measurement paths. Furthermore, the transmitter interface supplies floating DC power for compatible 2-wire and 3-wire field devices.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the MU-GAIH13 support direct connection of 4-20 mA transmitters?\u003cbr\u003eA: Yes. The module interfaces with 2-wire and 3-wire transmitters using 4-20 mA DC input signals and provides transmitter excitation capability.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of galvanic isolation in the MU-GAIH13?\u003cbr\u003eA: Galvanic isolation separates field signal circuits from control electronics to reduce ground loop effects and prevent electrical interference from affecting I\/O processing.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MU-GAIH13 operate in redundant system configurations?\u003cbr\u003eA: The supplied data indicates redundancy support capability; however, specific redundancy switching behavior depends on the installed Honeywell controller and I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the MU-GAIH13 according to the Honeywell cabinet layout and FTA mounting requirements.\u003c\/li\u003e\n\u003cli\u003eUse the specified compression terminals for field wiring termination and verify conductor tightness before commissioning.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-voltage power cables to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eApply proper shield grounding practices according to the control system installation standard.\u003c\/li\u003e\n\u003cli\u003eConfirm transmitter polarity, loop wiring configuration, and signal range before connecting field devices.\u003c\/li\u003e\n\u003cli\u003eVerify galvanic isolation performance during commissioning by checking field-to-system electrical separation.\u003c\/li\u003e\n\u003cli\u003eInspect conformal coating condition when installing or servicing the module in corrosive environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44480392298584,"sku":"MU-GAIH13 51304718-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MU-GAIH1351304718-100-3.jpg?v=1785407211","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-mu-gaih13-galvanically-isolated-high-level-analog-input-fta","provider":"IndustriaX Limited","version":"1.0","type":"link"}