{"product_id":"honeywell-mc-tail02-low-level-analog-input-field-termination-assembly","title":"Honeywell MC-TAIL02 Low-Level Analog Input Field Termination Assembly","description":"\u003ch2\u003eHoneywell MC-TAIL02 Low-Level Analog Input Field Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-TAIL02 51304437-150\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC-TAIL02\u003c\/strong\u003e Low-Level Analog Input Field Termination Assembly, operates as a dedicated hardware component for low-level temperature and millivolt signal termination within Honeywell Experion PKS and TDC 3000 HPM systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TAIL02 51304437-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in available data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eLow-Level Analog Input Field Termination Assembly (LLAI FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple, RTD, millivolt signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e8 or 16 channels depending on system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC channel-to-ground \/ 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting or cabinet mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Functions\u003c\/td\u003e\n\u003ctd\u003eField signal termination, routing, filtering, and transient protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell DCS Analog Signal Conditioning Features\u003c\/h3\u003e\n\u003cp\u003eThe MC-TAIL02 performs low-level analog signal termination for temperature measurement devices connected to Honeywell process control platforms. It accepts thermocouple, RTD, and millivolt inputs, then routes conditioned signals to the associated I\/O processing hardware.\u003c\/p\u003e\n\u003cp\u003eIn addition, the assembly supports channel-to-channel isolation functions that reduce interference between measurement circuits. The termination design incorporates filtering and surge protection components to limit electrical disturbances from field wiring.\u003c\/p\u003e\n\u003cp\u003eFor temperature measurement applications, the FTA supports cold junction compensation (CJC) functions when used with compatible Honeywell input processing modules. Therefore, the system can maintain thermocouple measurement accuracy by compensating for reference junction temperature variations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What field signals can the Honeywell MC-TAIL02 51304437-150 accept?\u003cbr\u003eA: The MC-TAIL02 accepts low-level analog signals including thermocouples, RTDs, and millivolt sources. The connected I\/O module determines the final signal processing configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MC-TAIL02 provide electrical isolation for field inputs?\u003cbr\u003eA: Yes. The assembly provides channel-to-ground isolation to separate field signal circuits from system electronics and reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MC-TAIL02 be replaced without disconnecting field wiring?\u003cbr\u003eA: The FTA design allows field wiring to remain connected during module service activities. Maintenance procedures must follow the specific Honeywell cabinet and system shutdown requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the MC-TAIL02 in the designated Honeywell control cabinet location using the approved mounting hardware.\u003c\/li\u003e\n\u003cli\u003eVerify that terminal assignments match the configured I\/O channel mapping before connecting field devices.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cable for thermocouple, RTD, and millivolt signal wiring where required by the process environment.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the Honeywell grounding specification to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level analog signal cables from high-voltage power wiring and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm field sensor polarity, terminal tightness, and grounding continuity before system commissioning.\u003c\/li\u003e\n\u003cli\u003eCheck that the connected I\/O processor configuration matches the installed FTA signal type and channel allocation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44494965112920,"sku":"MC-TAIL02 51304437-150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MC-TAIL02-51304437-150-3_1200x1200_f2460c93-a441-4439-80c1-f782cd3cc183.jpg?v=1785751913","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-mc-tail02-low-level-analog-input-field-termination-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}