{"product_id":"honeywell-fc-tro-0824-digital-output-module","title":"Honeywell FC-TRO-0824 Digital Output Module","description":"\u003ch2\u003eHoneywell FC-TRO-0824 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for non-safe relay output execution in Honeywell Safety Manager and Fail Safe Controller platforms, the \u003cstrong\u003eHoneywell FC-TRO-0824\u003c\/strong\u003e (\u003cstrong\u003eTRO-0824\u003c\/strong\u003e Digital Output Module) provides direct physical switching control through eight potential-free relay changeover contacts.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TRO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eNon-safe Dry Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 x 6.5 x 11.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypically 27 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eDigital output interface with relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contact Type\u003c\/td\u003e\n\u003ctd\u003eNO\/NC relay changeover contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e31 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Cut-in Voltage\u003c\/td\u003e\n\u003ctd\u003e19 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC \/ 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switched Load\u003c\/td\u003e\n\u003ctd\u003e1250 VA \/ 150 W at 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, UL, TUV, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipment Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterconnection\u003c\/td\u003e\n\u003ctd\u003eEight-channel relay output FTA cable interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Process Control Interface\u003c\/h3\u003e\n\u003cp\u003eThe FC-TRO-0824 provides eight independent relay output channels for switching external field devices through dry potential-free contacts. The module uses relay changeover contacts with NO and NC configurations, allowing direct control of external circuits without applying field voltage to the output contacts.\u003c\/p\u003e\n\u003cp\u003eHoneywell process control modules commonly integrate channel-to-channel isolation concepts to separate field circuits and reduce electrical interference between I\/O points. The FC-TRO-0824 applies relay-based signal separation for non-safe digital output applications where discrete electrical switching is required.\u003c\/p\u003e\n\u003cp\u003eThe module accepts a 24 V DC supply input and operates with a typical input current of 27 mA. It supports AC and DC switching loads within the specified voltage and current limits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of signals does the FC-TRO-0824 output?\u003cbr\u003eA: The FC-TRO-0824 provides eight non-safe dry digital outputs using potential-free relay changeover contacts with NO and NC terminals.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum switching capability of the FC-TRO-0824 relay outputs?\u003cbr\u003eA: Each output supports up to 5 A switching current, with maximum ratings of 250 V AC or 300 V DC and a maximum switched load of 1250 VA or 150 W at 30 V DC.\u003c\/p\u003e\n\u003cp\u003eQ: Can the FC-TRO-0824 be used for safety shutdown functions?\u003cbr\u003eA: The FC-TRO-0824 is specified as a non-safe digital output module and should not be configured as a safety-rated output device.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the FC-TRO-0824 within the designated Honeywell controller or I\/O assembly according to the system hardware manual.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 V DC supply polarity before energizing the module.\u003c\/li\u003e\n\u003cli\u003eUse appropriate field wiring practices for relay contacts, including separation between low-level signal cables and high-voltage switching circuits.\u003c\/li\u003e\n\u003cli\u003eConnect the interconnection cable correctly to maintain channel assignment and relay contact mapping.\u003c\/li\u003e\n\u003cli\u003eGround cable shields according to the control cabinet grounding standard to reduce electrical noise.\u003c\/li\u003e\n\u003cli\u003eConfirm external load ratings remain within the specified relay voltage, current, and power limits before commissioning.\u003c\/li\u003e\n\u003cli\u003eInspect relay contact wiring periodically when switching inductive loads or high-frequency operating cycles.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44477091577944,"sku":"FC-TRO-0824","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-TRO-0824-2.jpg?v=1785322945","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-fc-tro-0824-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}