{"product_id":"honeywell-fc-tdol-0724-digital-output-fta","title":"Honeywell FC-TDOL-0724 Digital Output FTA","description":"\u003ch2\u003eHoneywell FC-TDOL-0724 Digital Output FTA\u003c\/h2\u003e\n\u003cp\u003eConfigured for line-monitored relay contact digital output execution in Honeywell Safety Manager and process control I\/O systems, the \u003cstrong\u003eHoneywell FC-TDOL-0724\u003c\/strong\u003e (\u003cstrong\u003eFC-TDOL-0724\u003c\/strong\u003e Digital Output FTA) provides direct physical\/electrical execution for seven-channel field switching circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TDOL-0724\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eLine-monitored relay contact digital output interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC or 120 VDC +\/- 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Rating AC\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Rating DC\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Required Field Load\u003c\/td\u003e\n\u003ctd\u003e1 Watt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current to Load\u003c\/td\u003e\n\u003ctd\u003eMax. 1 mA at 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Detection Load Threshold\u003c\/td\u003e\n\u003ctd\u003e200 ohm \u0026lt; RTh \u0026lt; 400 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e1 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Configuration\u003c\/td\u003e\n\u003ctd\u003eOne relay with indicator LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eFused 2 AT contact output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Injection Resistor\u003c\/td\u003e\n\u003ctd\u003e22 k ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e24 x 10.8 x 8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, TUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipment Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Digital Output Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FC-TDOL-0724 provides seven relay contact output channels with line monitoring capability. Therefore, the module supervises field circuit conditions through current injection and load threshold detection.\u003c\/p\u003e\n\u003cp\u003eThe output design includes a 22 k ohm current injection resistor and a fused 2 AT contact output path. Additionally, the module uses an indicator LED for relay status visualization during operation.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell process control architectures, field I\/O modules require controlled signal handling and channel-to-channel isolation practices. The FC-TDOL-0724 follows these installation principles by separating field switching circuits from internal control electronics.\u003c\/p\u003e\n\u003cp\u003eThe module supports digital switching applications where the field load operates at 120 VAC or 120 VDC within the specified voltage range.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many output channels does the FC-TDOL-0724 provide?\u003cbr\u003eA: The FC-TDOL-0724 provides 7 relay contact digital output channels.\u003c\/p\u003e\n\u003cp\u003eQ: What field monitoring function does the module support?\u003cbr\u003eA: The module supports line monitoring through current injection and short-circuit detection load threshold measurement.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field output protection does the module include?\u003cbr\u003eA: The module includes a fused 2 AT contact output and a relay output circuit with indicator LED status display.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the FC-TDOL-0724 in the designated Honeywell I\/O termination and field interface assembly according to system configuration requirements.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring polarity and voltage levels before connecting the relay output terminals.\u003c\/li\u003e\n\u003cli\u003eSeparate digital output wiring from high-current power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the plant grounding standard and maintain proper shield termination practices.\u003c\/li\u003e\n\u003cli\u003eCheck field load characteristics before commissioning to confirm compatibility with the module output rating.\u003c\/li\u003e\n\u003cli\u003eInspect fuse condition, relay indicator operation, and terminal connections during maintenance procedures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44476882387032,"sku":"FC-TDOL-0724","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-TDOL-0724-3.jpg?v=1785320592","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-fc-tdol-0724-digital-output-fta","provider":"IndustriaX Limited","version":"1.0","type":"link"}