{"product_id":"honeywell-fc-sdo-0824m-safe-digital-output-module","title":"Honeywell FC-SDO-0824M Safe Digital Output Module","description":"\u003ch2\u003eHoneywell FC-SDO-0824M Safe Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-SDO-0824M\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-SDO-0824\u003c\/strong\u003e Safe Digital Output Module, operates as a dedicated hardware component for fail-safe 24 VDC signal execution within Honeywell Safety Manager and Fail Safe Controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-SDO-0824M \/ FC-SDO-0824 CC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified in available documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE (4 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC: 25 mA; 24 VDC internal: 25 mA; 24 VDC field supply: 70 mA without output load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSafe Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Capability\u003c\/td\u003e\n\u003ctd\u003eSIL 2 \/ SIL 3 capable according to IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 safety digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Arrangement\u003c\/td\u003e\n\u003ctd\u003e2 groups of 4 channels with independent SMOD capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC solid-state sourcing output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Channel Current\u003c\/td\u003e\n\u003ctd\u003e550 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Power Capacity\u003c\/td\u003e\n\u003ctd\u003e13 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Load Capacity\u003c\/td\u003e\n\u003ctd\u003e120 mA, 2.9 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003eLess than 2.0 VDC at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003eLess than 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacitance\u003c\/td\u003e\n\u003ctd\u003e1 uF maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic current limiting and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated suppression diode for inductive loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating available on M \/ CC variants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Safety Manager Fail-Safe Output Execution\u003c\/h3\u003e\n\u003cp\u003eThe FC-SDO-0824M provides solid-state 24 VDC output switching for safety-related field devices. It controls external actuators, relays, solenoids, and indication devices through eight independent output channels.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module divides outputs into two isolated groups of four channels. Each group includes a Secondary Means of De-energizing (SMOD), allowing the controller and watchdog circuits to remove output power during detected faults.\u003c\/p\u003e\n\u003cp\u003eThe module performs continuous self-diagnostic routines during configured test intervals. These diagnostics verify output shutdown capability, suppression diode condition, and channel interaction behavior without interrupting normal process operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the FC-SDO-0824M support inductive field loads?\u003cbr\u003eA: Yes. Each output channel includes an integrated suppression diode that manages inductive voltage spikes from devices such as solenoids and relays.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module achieve fail-safe output shutdown?\u003cbr\u003eA: The module uses independent SMOD circuits for two output groups, allowing the processor and watchdog functions to force outputs into a safe de-energized state.\u003c\/p\u003e\n\u003cp\u003eQ: Can the output channels operate continuously at maximum current?\u003cbr\u003eA: The module supports up to 550 mA per channel, with current derating required at elevated operating temperatures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the FC-SDO-0824M in the specified Honeywell Safety Manager or FSC I\/O chassis position.\u003c\/li\u003e\n\u003cli\u003eVerify module key coding before insertion to prevent installation in an incompatible chassis slot.\u003c\/li\u003e\n\u003cli\u003eConnect 24 VDC field wiring according to the approved terminal assignment documentation.\u003c\/li\u003e\n\u003cli\u003eSeparate output wiring from high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate grounding methods for cabinet shields and cable screens according to site electrical standards.\u003c\/li\u003e\n\u003cli\u003eConfirm field actuator ratings before connection to ensure compatibility with the 550 mA channel current limitation.\u003c\/li\u003e\n\u003cli\u003ePerform diagnostic verification after installation to confirm output switching and fail-safe de-energization functions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44477096722520,"sku":"FC-SDO-0824M","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-SDO-0824M-2.jpg?v=1785323128","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-fc-sdo-0824m-safe-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}