{"product_id":"honeywell-fc-rusio-3224-remote-universal-safe-i-o-module","title":"Honeywell FC-RUSIO-3224 Remote Universal Safe I\/O Module","description":"\u003ch2\u003eHoneywell FC-RUSIO-3224 Remote Universal Safe I\/O Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for universal safety signal processing in Honeywell Safety Manager SIS platforms, the \u003cstrong\u003eHoneywell FC-RUSIO-3224\u003c\/strong\u003e (\u003cstrong\u003eFC-RUSIO-3224\u003c\/strong\u003e Remote Universal Safe I\/O Module) provides direct physical and electrical execution for configurable 32-channel field I\/O operations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-RUSIO-3224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRemote Universal Safe I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ Safety Manager SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.2 x 15.5 x 16.5 cm (estimated shipping size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied from 24 VDC field power source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 universal safe I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC -20% to +30%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClosed Contact Current\u003c\/td\u003e\n\u003ctd\u003e7 mA +\/- 5% at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Contact Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 4 mA +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Resistor\u003c\/td\u003e\n\u003ctd\u003e1 kOhm +\/- 5%, \u0026gt;0.25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Detection\u003c\/td\u003e\n\u003ctd\u003eField resistance \u0026lt; 500 Ohm +\/- 50%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Off Delay After ESD\u003c\/td\u003e\n\u003ctd\u003e10 ms +\/- 30%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL 3 applications according to IEC 61508 \/ IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Process Signal Isolation and Safety I\/O Architecture\u003c\/h3\u003e\n\u003cp\u003eThe FC-RUSIO-3224 uses a universal channel architecture where each of the 32 channels can be configured through Safety Builder software. Therefore, one hardware module can execute multiple signal functions without requiring separate digital and analog module types.\u003c\/p\u003e\n\u003cp\u003eThe module supports digital input operation with or without line monitoring, digital output operation with loop monitoring, analog input operation in 0-20 mA or 4-20 mA active modes, and analog output operation with open circuit detection. In addition, the module supports one ESD input with line monitoring capability.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell SIS applications, the module maintains channel-to-channel isolation for field signal processing and supports monitored 4-20 mA current loop interfaces. Moreover, the configurable I\/O design allows process transmitters, switches, actuators, and shutdown devices to connect through the same physical module platform.\u003c\/p\u003e\n\u003cp\u003eThe FC-RUSIO-3224 requires two modules to create a redundant configuration. Each module receives power from the 24 VDC supply, while the Safety Manager controller supervises configured safety functions and field signal states.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FC-RUSIO-3224 channels be configured as different signal types on the same module?\u003cbr\u003eA: Yes. Each of the 32 channels can be individually configured through Safety Builder software as digital input, digital output, analog input, or analog output.\u003c\/p\u003e\n\u003cp\u003eQ: Does the FC-RUSIO-3224 support redundant safety configurations?\u003cbr\u003eA: Yes. Two FC-RUSIO-3224 modules are required to achieve a redundant configuration for SIL 3 safety applications.\u003c\/p\u003e\n\u003cp\u003eQ: What field monitoring functions are available on this module?\u003cbr\u003eA: The module supports line monitoring for digital inputs, loop monitoring for digital outputs, and open circuit detection for analog output channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the FC-RUSIO-3224 inside the designated Honeywell Safety Manager cabinet assembly according to system engineering drawings.\u003c\/p\u003e\n\u003cp\u003eUse shielded field cables for analog signal wiring and connect cable shields according to the cabinet grounding specification. Moreover, separate low-level analog wiring from high-voltage power conductors to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eVerify the 24 VDC supply polarity before energizing the module. Confirm that field device wiring matches the channel configuration defined in Safety Builder before performing commissioning tests.\u003c\/p\u003e\n\u003cp\u003eCheck terminal connections, field resistance values, and loop continuity during installation. Therefore, complete channel diagnostics and safety function verification before placing the SIS application into operational service.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44376314413144,"sku":"FC-RUSIO-3224","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-RUSIO-3224-2.jpg?v=1784016107","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-fc-rusio-3224-remote-universal-safe-i-o-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}