{"product_id":"honeywell-fc-gmld16-gas-and-smoke-detector-input-module","title":"Honeywell FC-GMLD16 Gas and Smoke Detector Input Module","description":"\u003ch2\u003eHoneywell FC-GMLD16 Gas and Smoke Detector Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-GMLD16\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-GMLD16\u003c\/strong\u003e Gas and Smoke Detector Input Module, operates as a dedicated hardware component for monitoring detector loop signals within Honeywell Safety Manager and Fail Safe Controller systems. The module processes 16 field detector channels and performs loop status supervision with open-circuit and short-circuit diagnostics.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-GMLD16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-5 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 W to 5 W depending on loop load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eGas \/ Smoke Detector Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ Fail Safe Controller (FSC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 independent detector input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 VDC to 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Loop Monitoring\u003c\/td\u003e\n\u003ctd\u003eOpen-circuit and short-circuit detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-bus galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eFSC \/ Safety Manager I\/O rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Safety Loop Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FC-GMLD16 applies channel-to-channel isolation methods to separate detector loop circuits and reduce interference between field inputs. Each channel independently evaluates gas and smoke detector loop conditions, while the module reports input status and fault states through the Safety Manager or FSC controller backplane.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module continuously supervises field wiring integrity. It detects abnormal loop conditions, including open wiring and short circuits, allowing the safety controller to identify field connection faults before they affect protective functions.\u003c\/p\u003e\n\u003cp\u003eThe FC-GMLD16 follows Honeywell safety system design practices for SIS applications, where diagnostic coverage and deterministic input processing support safety-related shutdown logic execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many detector loops can the FC-GMLD16 process simultaneously?\u003cbr\u003eA: The FC-GMLD16 supports 16 independent gas or smoke detector input channels within one I\/O module.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module detect field wiring faults?\u003cbr\u003eA: Yes. The module monitors detector loops and identifies open-circuit and short-circuit conditions through integrated line fault diagnostics.\u003c\/p\u003e\n\u003cp\u003eQ: Can the FC-GMLD16 be replaced during system operation?\u003cbr\u003eA: The module supports hot-swap replacement when the installed Honeywell FSC or Safety Manager configuration permits live module exchange procedures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the FC-GMLD16 only in compatible Honeywell FSC or Safety Manager I\/O rack positions.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 VDC power supply polarity and voltage range before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eRoute detector loop cables separately from high-voltage power cables to reduce electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003eUse proper shield termination practices according to the site grounding design and Honeywell installation documentation.\u003c\/li\u003e\n\u003cli\u003eConfirm each detector loop wiring connection before system commissioning.\u003c\/li\u003e\n\u003cli\u003eCheck channel status indicators after installation to verify normal input operation and fault-free field connections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44477052125272,"sku":"FC-GMLD16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-GMLD16.jpg?v=1785322140","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-fc-gmld16-gas-and-smoke-detector-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}