{"product_id":"honeywell-cc-tuio31-universal-input-output-iota","title":"Honeywell CC-TUIO31 Universal Input Output IOTA","description":"\u003ch2\u003eHoneywell CC-TUIO31 Universal Input Output IOTA\u003c\/h2\u003e\n\u003cp\u003eConfigured for universal field signal termination and analog I\/O execution in Honeywell Experion PKS control platforms, the \u003cstrong\u003eHoneywell CC-TUIO31\u003c\/strong\u003e (\u003cstrong\u003eCC-TUIO31\u003c\/strong\u003e Universal Input Output IOTA) provides direct physical and electrical interface functions for current input devices and configurable analog\/digital output channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TUIO31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Input Output IOTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 x 16 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C module ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent input for 2, 3, or 4 wire devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Scan Rate\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003eAny 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Input Range\u003c\/td\u003e\n\u003ctd\u003e0-15 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection Ratio\u003c\/td\u003e\n\u003ctd\u003e18 dB at 50 Hz, 20 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrosstalk (DC to 60 Hz, channel-to-channel)\u003c\/td\u003e\n\u003ctd\u003e60 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic short circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Communication Support\u003c\/td\u003e\n\u003ctd\u003eHART 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Interface\u003c\/td\u003e\n\u003ctd\u003eHART modem per channel for fast performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Function\u003c\/td\u003e\n\u003ctd\u003eFast Scan (Priority I\/O Module Scan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe State Function\u003c\/td\u003e\n\u003ctd\u003eConfigurable FAILOPT behavior for Digital \/ Analog Output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation Features\u003c\/h3\u003e\n\u003cp\u003eThe CC-TUIO31 is designed for process instrumentation signal handling within Honeywell control architectures. The module supports 4-20 mA current loops with HART 7 communication capability, allowing analog measurement signals and device diagnostic communication to be processed through the same field wiring interface.\u003c\/p\u003e\n\u003cp\u003eChannel-to-channel crosstalk performance is specified at 60 dB from DC to 60 Hz. The module provides configurable channel behavior for analog and digital output safe-state handling, with electronic short circuit protection applied to output circuits.\u003c\/p\u003e\n\u003cp\u003eThe input subsystem uses a 16 bit A\/D converter with a 10 ms input scan rate, supporting configurable field device connections including 2 wire, 3 wire, and 4 wire current devices.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of field signals can the CC-TUIO31 process?\u003cbr\u003eA: The CC-TUIO31 processes current-based field signals using 0-20 mA or 4-20 mA input ranges and supports 2 wire, 3 wire, and 4 wire device configurations.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CC-TUIO31 support HART communication?\u003cbr\u003eA: Yes. The module supports HART 7 communication through a dedicated HART modem per channel for analog I\/O device communication.\u003c\/p\u003e\n\u003cp\u003eQ: How are output fault conditions handled by the module?\u003cbr\u003eA: Digital and analog output channels support configurable FAILOPT safe-state behavior, and output circuits include electronic short circuit protection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CC-TUIO31 according to Honeywell Experion PKS I\/O assembly installation procedures and approved cabinet layouts.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring polarity and terminal assignments before applying power to the I\/O assembly.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cable for analog current loops where required by site electrical standards.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the plant grounding specification to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-current power conductors and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm that connected field devices match the configured 2 wire, 3 wire, or 4 wire current input arrangement.\u003c\/li\u003e\n\u003cli\u003eValidate HART communication wiring integrity when using smart field transmitters.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44345394823256,"sku":"CC-TUIO31 51306875-176","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-TUIO3151306875-176-3.jpg?v=1783491226","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-cc-tuio31-universal-input-output-iota","provider":"IndustriaX Limited","version":"1.0","type":"link"}