{"product_id":"honeywell-cc-taon11-series-c-analog-output-iota","title":"Honeywell CC-TAON11 Series C Analog Output IOTA","description":"\u003ch2\u003eHoneywell CC-TAON11 Series C Analog Output IOTA\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog output signal termination in the Honeywell Experion PKS Series C system, the \u003cstrong\u003eHoneywell CC-TAON11 (51306521-175)\u003c\/strong\u003e (\u003cstrong\u003eCC-TAON11\u003c\/strong\u003e Analog Output IOTA) provides direct electrical execution. It functions as the termination interface between Series C analog output modules and field devices, routing controller-generated 4-20 mA output signals to external loads while supporting redundant I\/O configurations.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies a single catalog number only. No official suffix or option matrix is specified.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAON11 (51306521-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.4 kg to 0.56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Input Output Termination Assembly (IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNon-HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupports redundant configuration (12-inch version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit or 16-bit processing (depends on paired I\/O module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003eLess than 100 mV peak-to-peak across a 250 Ohm load at power line frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Readback Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 4 % of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Linearity\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05 % of full scale nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e0.005 % of full scale per deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between channels and power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 % to 95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe CC-TAON11 provides galvanic isolation between field channels and the power supply to reduce the transfer of electrical disturbances into analog output circuits. The assembly is intended for standard 4-20 mA control loops and does not implement HART communication. Internal diagnostics support output signal verification, while open-wire detection identifies interrupted field wiring connected to actuators or other analog loads.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CC-TAON11 support HART communication?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The documented version is a non-HART Analog Output IOTA intended for standard 4-20 mA analog output applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module be installed in a redundant I\/O configuration?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The documentation specifies support for redundant configuration when used with the applicable 12-inch redundant arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the termination assembly require firmware updates?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No firmware information is specified for the IOTA itself. Functional compatibility depends on the associated Series C analog output module and the Experion PKS hardware configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the IOTA securely on the designated DIN rail inside the Series C cabinet.\u003c\/li\u003e\n\u003cli\u003eVerify that the installed analog output module matches the specified CC-TAON11 termination assembly before field wiring.\u003c\/li\u003e\n\u003cli\u003eRoute analog output wiring separately from high-voltage or high-current conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the cabinet grounding practice defined for the control system, avoiding multiple shield ground points unless required by the installation standard.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal identification before energizing field circuits and verify continuity if open-wire diagnostics indicate a disconnected load.\u003c\/li\u003e\n\u003cli\u003eObserve the specified environmental limits for operating temperature and humidity during installation and operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44306798805080,"sku":"CC-TAON11 51306521-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-TAON1151306521-175-3.jpg?v=1782979962","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-cc-taon11-series-c-analog-output-iota","provider":"IndustriaX Limited","version":"1.0","type":"link"}