{"product_id":"honeywell-cc-paih02-51405038-375-analog-input-module","title":"Honeywell CC-PAIH02 51405038-375 Analog Input Module","description":"\u003ch2\u003eHoneywell CC-PAIH02 51405038-375 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for multi-channel field signal acquisition in Honeywell Experion PKS C300 controller architectures, the \u003cstrong\u003eHoneywell CC-PAIH02 51405038-375\u003c\/strong\u003e (\u003cstrong\u003eCC-PAIH02\u003c\/strong\u003e Analog Input Module) provides direct electrical conditioning and A\/D conversion of process-level analog signals into controller-readable digital data within distributed I\/O backplane environments.\u003c\/p\u003e\n\u003cp\u003eThe module supports 16 channel differential\/single-ended input acquisition for 2-wire or self-powered transmitters. It processes 4-20 mA and voltage signals through configurable input ranges with 16-bit resolution conversion. Channel acquisition is executed via a 50 ms scan cycle, with integrated filtering and rejection mechanisms for industrial noise environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model: CC-PAIH02\u003c\/li\u003e\n\u003cli\u003eOrder Number: 51405038-375\u003c\/li\u003e\n\u003cli\u003eModule Class: Analog Input Module\u003c\/li\u003e\n\u003cli\u003eFunctional Variant: High level analog input with multi-range conditioning\u003cbr\u003eNo additional decoded hierarchy is defined in manufacturer documentation for suffix segmentation beyond ordering and base functional class.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAIH02 51405038-375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6 x 15.5 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e2-wire or self-powered transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0-5 V, 1-5 V, 0.4-2 V, 4-20 mA (250 ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e70 dB (dc to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e19 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 M ohm (powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input\u003c\/td\u003e\n\u003ctd\u003e+\/- 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrosstalk\u003c\/td\u003e\n\u003ctd\u003e-60 dB (dc to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Process Signal Conditioning Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module implements channel-level analog signal conditioning consistent with Honeywell Experion PKS I\/O architecture. Each input channel supports loop-powered 4-20 mA acquisition through precision shunt conversion (250 ohm equivalent scaling path), enabling direct interfacing with field transmitters under HART-capable process loops. Differential measurement paths are designed to maintain channel integrity under common-mode voltage excursions within defined industrial limits, with multi-stage filtering providing attenuation of normal-mode interference prior to A\/D conversion. Backplane communication ensures synchronized scan scheduling with controller execution cycles, maintaining deterministic update behavior across distributed I\/O nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-PAIH02 support hot-swap replacement during controller operation?\u003cbr\u003eA: Hot-swap capability depends on system rack configuration. Electrically, the module is designed for backplane isolation; however, insertion\/removal should follow system-level maintenance procedures to avoid bus disruption.\u003c\/p\u003e\n\u003cp\u003eQ: What is the impact of channel-to-channel interaction under high-density loading?\u003cbr\u003eA: Crosstalk is specified at -60 dB (dc to 60 Hz), indicating low inter-channel coupling under normal operating bandwidth, assuming correct grounding and shield termination practices.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module directly interface with both voltage and current inputs simultaneously?\u003cbr\u003eA: Yes. Input channels are configurable for 0-5 V, 1-5 V, 0.4-2 V, and 4-20 mA signal types, but configuration must be consistent per channel grouping rules defined at system integration level.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall module in designated Experion PKS I\/O chassis slot with verified backplane alignment.\u003c\/li\u003e\n\u003cli\u003eMaintain shield continuity and terminate cable shields at designated grounding points only.\u003c\/li\u003e\n\u003cli\u003eSeparate analog input wiring from high-voltage switching conductors to reduce electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eEnsure correct configuration of channel input type before energizing field loops.\u003c\/li\u003e\n\u003cli\u003eVerify loop power compatibility for 2-wire transmitters prior to connection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44339171819608,"sku":"CC-PAIH02 51405038-375","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-PAIH0251405038-375-3.jpg?v=1783334835","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-cc-paih02-51405038-375-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}