{"product_id":"honeywell-900g02-0102-digital-input-module","title":"Honeywell 900G02-0102 Digital Input Module","description":"\u003ch2\u003eHoneywell 900G02-0102 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in the Honeywell ControlEdge HC900 control system, the \u003cstrong\u003eHoneywell 900G02-0102\u003c\/strong\u003e (\u003cstrong\u003e900G02-0102\u003c\/strong\u003e Digital Input Module) provides direct electrical monitoring of 16 digital field input channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900G02-0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell ControlEdge HC900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.3 x 14.1 x 3.2 cm (shipping size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Process Signal Interface\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 900G02-0102 provides 16 digital input channels for monitoring binary field devices within the HC900 controller architecture. The module receives discrete electrical states from connected field devices and transfers status information through the controller backplane interface.\u003c\/p\u003e\n\u003cp\u003eThe module design supports process control applications that require channel-to-channel signal separation and stable digital status detection. Therefore, installation should maintain proper field wiring practices to reduce electrical interference and signal distortion.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of signals does the Honeywell 900G02-0102 process?\u003cbr\u003eA: The 900G02-0102 is a digital input module designed to process discrete ON\/OFF field signals through 16 input channels.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 900G02-0102 operate as a standalone input device?\u003cbr\u003eA: No. The module requires installation within the Honeywell ControlEdge HC900 hardware platform and communicates through the system backplane.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 900G02-0102 available as a current production module?\u003cbr\u003eA: The manufacturer has discontinued the 900G02-0102 model. Existing installations may continue using supported spare or replacement strategies defined by the control system configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 900G02-0102 module in the designated HC900 rack position according to the controller hardware configuration manual.\u003c\/p\u003e\n\u003cp\u003eConnect field input wiring using proper industrial control cabinet practices. Separate digital signal cables from high-voltage power conductors to minimize electromagnetic interference. Maintain correct terminal identification during wiring replacement or maintenance activities.\u003c\/p\u003e\n\u003cp\u003eVerify module seating, backplane engagement, and cabinet grounding before system startup. Use shielded cables where required by the field device installation standard, and connect shields according to the plant grounding procedure.\u003c\/p\u003e\n\u003cp\u003eConfirm the controller configuration database matches the installed module type before returning the control system to operation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44503139876952,"sku":"900G02-0102","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/900G02-0102-3_1200x1200_bb627ff6-cd39-4ee3-9354-b647136a2392.jpg?v=1785920314","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-900g02-0102-digital-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}