{"product_id":"honeywell-900b08-0202-analog-output-module","title":"Honeywell 900B08-0202 Analog Output Module","description":"\u003ch2\u003eHoneywell 900B08-0202 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900B08-0202\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900B08-0202\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for isolated current signal output execution within the Honeywell ControlEdge HC900 controller platform.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900B08-0202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.5 x 15.2 x 3.5 cm (estimated shipping size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC: 40 mA max; 24 VDC: 200 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4 isolated outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0 to 21.8 mA, selectable range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd\u003e750 ohms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation Channel to Channel\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation from Logic\u003c\/td\u003e\n\u003ctd\u003e600 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% full scale at reference conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\/A Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Current Sensing\u003c\/td\u003e\n\u003ctd\u003eGreater than 3.5 mA per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Modules per Rack\u003c\/td\u003e\n\u003ctd\u003e10 modules standard; up to 12 modules with ambient temperature derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipment Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop and Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 900B08-0202 provides isolated analog current outputs for process control signal transmission. The module uses individual output channel isolation to reduce electrical interference between field circuits. Additionally, the galvanic isolation design supports separation between output wiring and controller logic circuits.\u003c\/p\u003e\n\u003cp\u003eThe module supports selectable current output operation from 0 to 21.8 mA, which allows connection with standard industrial analog receiving devices. Furthermore, the 12-bit D\/A conversion provides controlled current signal generation for process loop applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many analog output channels does the Honeywell 900B08-0202 provide?\u003cbr\u003eA: The 900B08-0202 provides 4 isolated analog output channels with selectable current output ranges.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation levels are available on the 900B08-0202 module?\u003cbr\u003eA: The module provides 500 VDC channel-to-channel galvanic isolation and 600 VDC isolation from the controller logic section.\u003c\/p\u003e\n\u003cp\u003eQ: What rack installation limits apply to the 900B08-0202?\u003cbr\u003eA: The module supports up to 10 modules per rack under standard conditions. A maximum of 12 modules requires ambient temperature derating consideration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 900B08-0202 module only in the designated Honeywell ControlEdge HC900 I\/O rack position. Verify that the controller rack power is removed before module insertion or removal.\u003c\/p\u003e\n\u003cp\u003eConnect analog output wiring using appropriate shielded industrial cables. Terminate cable shields according to the site grounding standard to reduce electromagnetic interference. Keep analog signal wiring separated from high-voltage power cables and switching circuits.\u003c\/p\u003e\n\u003cp\u003eConfirm field device load resistance compatibility before commissioning. Check output polarity, channel assignment, and current loop continuity before applying operating power.\u003c\/p\u003e\n\u003cp\u003eEnsure that rack loading remains within the specified power supply limits. Review module status indicators after installation to verify normal controller communication and output operation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44503228645464,"sku":"900B08-0202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/900B08-0202-3_1200x1200_6a7aa0c6-f101-4fd1-a454-ed466a32895b.jpg?v=1785922012","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-900b08-0202-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}