{"product_id":"honeywell-8c-td0da1-series-8-analog-output-module","title":"Honeywell 8C-TD0DA1 Series 8 Analog Output Module","description":"\u003ch2\u003eHoneywell 8C-TD0DA1 Series 8 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TD0DA1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8C-TD0DA1\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for generating 4-20 mA control signals within Honeywell Experion PKS Series 8 I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TD0DA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series 8 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit digital-to-analog conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% full scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eHART v5 \/ v6 \/ v7 pass-through support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system optical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC system bus supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eSeries 8 carrier \/ I\/O Module Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Process Control Interface\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8C-TD0DA1 integrates analog output channels with HART communication capability for process instrument control loops. Therefore, the module can transmit analog current signals while supporting digital device communication through the same field wiring path.\u003c\/p\u003e\n\u003cp\u003eThe module provides channel-level monitoring for output status, communication condition, and fault detection. In addition, the optical isolation structure separates field signal circuits from the system electronics to reduce interference effects in industrial installations.\u003c\/p\u003e\n\u003cp\u003eThe Series 8 architecture supports compact I\/O cabinet layouts while maintaining direct connection between the Experion PKS control strategy and field output devices such as control valves, actuators, and position controllers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 8C-TD0DA1 support HART communication on analog output channels?\u003cbr\u003eA: Yes. The module supports HART pass-through communication on 4-20 mA analog output channels for connected smart field devices.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 8C-TD0DA1 be replaced while the control system remains online?\u003cbr\u003eA: The Series 8 I\/O design supports hot-swap operation when installed in a compatible carrier and configured according to Honeywell system procedures.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field wiring isolation does the module provide?\u003cbr\u003eA: The module uses channel-to-system optical isolation to separate field output circuits from internal system electronics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the 8C-TD0DA1 module on the approved Honeywell Series 8 carrier assembly.\u003c\/li\u003e\n\u003cli\u003eVerify that the module position matches the configured Experion PKS I\/O database assignment before operation.\u003c\/li\u003e\n\u003cli\u003eUse shielded field cables for analog current loops when installed in areas with electrical noise sources.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding standard to reduce signal interference.\u003c\/li\u003e\n\u003cli\u003eSeparate analog output wiring from high-current power cables and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm 24 VDC system power availability before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eCheck channel configuration, output scaling, and HART communication status after installation.\u003c\/li\u003e\n\u003cli\u003eFollow Honeywell installation documentation for cabinet grounding, wiring termination, and maintenance procedures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44415492587608,"sku":"8C-TD0DA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/8C-TD0DA1.jpg?v=1784705006","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-8c-td0da1-series-8-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}