{"product_id":"honeywell-51304650-100-digital-output-field-termination-assembly","title":"Honeywell 51304650-100 Digital Output Field Termination Assembly","description":"\u003ch2\u003eHoneywell 51304650-100 Digital Output Field Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eConfigured for solid state digital output signal termination in Honeywell TDC 3000 and Experion PKS UCN\/HPM systems, the \u003cstrong\u003eHoneywell 51304650-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU-TD0D13\u003c\/strong\u003e Digital Output Field Termination Assembly, provides direct electrical interface execution between controller output logic and field devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-TD0D13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by connected field load and system interface requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51304650-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eTDC 3000 \/ Experion PKS HPM and UCN systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eDigital output interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSolid State Relay (SSR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e3 - 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003eGalvanic \/ optical isolation per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eStandard FTA assembly rack or DIN rail installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Isolation and Channel Interface\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 51304650-100 uses solid state relay channels to transfer digital output commands from the control system to external field circuits. Each output channel provides electrical isolation between the controller interface and connected devices, which reduces signal interference during switching operations.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module supports channel-to-channel isolation design for discrete output applications. Honeywell process control platforms use this type of termination assembly to maintain clear separation between controller logic signals and external electrical loads.\u003c\/p\u003e\n\u003cp\u003eThe module operates within the TDC 3000 and Experion PKS High-Performance Process Manager (HPM) I\/O architecture. Therefore, engineers can connect field devices such as solenoid valves, relay coils, indicator lamps, and actuator control circuits through a standardized termination interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of output switching device does the Honeywell 51304650-100 use?\u003c\/strong\u003e\u003cbr\u003eA: The module uses Solid State Relays (SSR) for digital output switching between the control system and connected field circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many digital output channels does the MU-TD0D13 provide?\u003c\/strong\u003e\u003cbr\u003eA: The MU-TD0D13 provides 16 digital output channels for field device control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module directly replace a controller I\/O card?\u003c\/strong\u003e\u003cbr\u003eA: No. The 51304650-100 functions as a Field Termination Assembly and requires compatibility with the designated Honeywell TDC 3000 or Experion PKS HPM\/UCN I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the Honeywell 51304650-100 according to the applicable TDC 3000 or Experion PKS hardware installation documentation.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring matches the assigned digital output channel configuration before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level control wiring from high-energy switching circuits to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to site grounding standards and avoid multiple grounding points that may create ground loops.\u003c\/li\u003e\n\u003cli\u003eConfirm that connected field loads operate within the specified 3 - 30 VDC output voltage range.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections for proper mechanical engagement before system commissioning.\u003c\/li\u003e\n\u003cli\u003eFollow approved shutdown procedures before removing or replacing the termination assembly.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44485266669656,"sku":"51304650-100 MU-TD0D13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/51304650-100MU-TD0D13-3.jpg?v=1785494415","url":"https:\/\/www.industriaxplc.com\/id\/products\/honeywell-51304650-100-digital-output-field-termination-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}