{"product_id":"ge-multilin-ur7jv-ur-7jv-universal-relay-module","title":"GE Multilin UR7JV UR-7JV Universal Relay Module","description":"\u003ch2\u003eGE Multilin UR7JV UR-7JV Universal Relay Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for microprocessor-based protection and control execution in GE Multilin Universal Relay (UR) platforms, the \u003cstrong\u003eGE Multilin UR7JV\u003c\/strong\u003e (\u003cstrong\u003eUR7JV\u003c\/strong\u003e Protection and Control Relay Module) provides direct physical\/electrical execution for current, voltage, digital input, relay output, and communication functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR7JV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin \/ GE Grid Solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor-Based Protection and Control Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e19-Inch Rack Mount \/ Panel Mount, 4RU Height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 15-25 W; Maximum 45 W depending on module load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Power Supply\u003c\/td\u003e\n\u003ctd\u003e110-250 VDC \/ 110-230 VAC (50\/60 Hz), or 24-48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e1 A or 5 A CT secondary selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Inputs\u003c\/td\u003e\n\u003ctd\u003e50-240 VAC nominal phase-to-neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003eOpto-isolated configurable threshold inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relays\u003c\/td\u003e\n\u003ctd\u003eForm-A \/ Form-C solid-state and mechanical relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Communication\u003c\/td\u003e\n\u003ctd\u003eSingle or redundant 10\/100Base-T RJ45 or 100Base-FX fiber optic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Communication\u003c\/td\u003e\n\u003ctd\u003eRS232 \/ RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, DNP 3.0, Modbus TCP\/IP, IEC 60870-5-104, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Synchronization\u003c\/td\u003e\n\u003ctd\u003eIRIG-B, IEEE 1588 PTP, SNTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP54 front panel, IP20 chassis and terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Network and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe GE Multilin UR7JV integrates industrial communication processing within the Universal Relay platform through Ethernet and serial interfaces. The module supports deterministic data exchange requirements for protection and control applications through IEC 61850, DNP 3.0, Modbus TCP\/IP, and IEC 60870-5-104 communication protocols.\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility is managed through the UR platform software environment, allowing controlled firmware loading and configuration transfer procedures. Network configuration, protection settings, and communication parameters are stored within the relay architecture for coordinated system operation.\u003c\/p\u003e\n\u003cp\u003eThe module supports configurable I\/O allocation, allowing scaling of current inputs, voltage measurement channels, digital status inputs, and trip output functions according to relay application requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of power supply inputs are supported by the UR7JV module?\u003cbr\u003eA: The module supports high range auxiliary power inputs of 110-250 VDC or 110-230 VAC at 50\/60 Hz, with an alternative low range supply option of 24-48 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: Does the UR7JV provide isolated field input processing?\u003cbr\u003eA: Yes. Digital inputs use opto-isolated circuits with configurable threshold voltage levels for external control signals.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interfaces are available on the UR7JV?\u003cbr\u003eA: The module supports Ethernet interfaces using RJ45 or fiber optic connections and serial communication through RS232 and RS485 interfaces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the relay module in a compatible 19-inch rack or panel mounting enclosure with adequate mechanical support.\u003c\/li\u003e\n\u003cli\u003eVerify auxiliary power supply voltage range before energizing the unit.\u003c\/li\u003e\n\u003cli\u003eSeparate CT, VT, control wiring, and communication cables to reduce electromagnetic interference coupling.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cables where required by the installation environment.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding practice and avoid multiple unintended grounding points.\u003c\/li\u003e\n\u003cli\u003eConfirm CT polarity, VT phase reference, and terminal identification before commissioning protection functions.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance between high voltage measurement wiring and low-level communication or control wiring.\u003c\/li\u003e\n\u003cli\u003eVerify firmware compatibility and relay configuration files before performing any software update procedure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44497695637592,"sku":"UR7JV","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/UR7JV.jpg?v=1785827503","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-multilin-ur7jv-ur-7jv-universal-relay-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}