{"product_id":"ge-multilin-ur6sh-ur-6sh-digital-input-output-module","title":"GE Multilin UR6SH UR-6SH Digital Input\/Output Module","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eGE Multilin UR6SH UR-6SH Digital Input\/Output Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for discrete contact output control and status monitoring in the GE Multilin Universal Relay system, the \u003cstrong\u003eGE Multilin UR6SH\u003c\/strong\u003e (\u003cstrong\u003eUR6SH\u003c\/strong\u003e Digital I\/O Module) provides direct physical\/electrical execution for protection and automation signal handling.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR6SH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input\/Output (I\/O) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003e6 Contact Outputs (2 x Form A, 4 x Form C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eSilver Alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V AC \/ 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current Rating\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake \u0026amp; Carry Current\u003c\/td\u003e\n\u003ctd\u003e30 A for 0.2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e0.5 A @ 125 V DC; 0.3 A @ 250 V DC (Resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Withstand\u003c\/td\u003e\n\u003ctd\u003e2000 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 100 M ohm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8 ms (Operate \/ Release)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e145 mm x 87 mm x 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP Deterministic Network and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe UR6SH module is designed as a plug-in hardware component within the GE Multilin Universal Relay chassis architecture. Its contact output density provides six discrete switching channels for trip circuits, breaker control interfaces, alarm annunciation, and inter-relay signaling applications.\u003c\/p\u003e\n\u003cp\u003eThe module supports industrial control architectures where deterministic signal execution and I\/O density scaling are required. The contact interface uses isolated electromechanical output paths with defined voltage, current, and dielectric withstand characteristics for connection to external control circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the UR6SH module hot-swappable within a GE Multilin UR chassis?\u003cbr\u003eA: The available documentation identifies the UR6SH as a modular plug-in card. Hot-swap operation should follow the specific GE Multilin UR chassis installation procedure and system maintenance requirements.\u003c\/p\u003e\n\u003cp\u003eQ: What type of external circuits can the UR6SH contact outputs control?\u003cbr\u003eA: The module provides Form A and Form C contact outputs suitable for discrete control functions including trip, close, alarm, and inter-relay signaling circuits within specified contact ratings.\u003c\/p\u003e\n\u003cp\u003eQ: Does the UR6SH require separate firmware compatibility management?\u003cbr\u003eA: Firmware compatibility is determined by the installed GE Multilin UR relay platform and chassis configuration. The module should be installed according to the applicable UR series hardware and firmware revision requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the UR6SH module into the designated GE Multilin UR chassis slot with power removed according to standard relay maintenance procedures.\u003c\/p\u003e\n\u003cp\u003eVerify terminal wiring against the applicable contact output configuration before energizing the relay system. Separate low-level communication wiring from high-energy switching circuits to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eUse appropriate shield termination practices for connected control wiring where required by the site grounding design. Confirm contact load characteristics, polarity requirements, and protective circuit arrangements before connecting external trip or control circuits.\u003c\/p\u003e\n\u003cp\u003eEnsure the module is mechanically seated in the chassis connector and that the retention hardware is secured before system commissioning.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44497884905560,"sku":"UR6SH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/UR6LV2_30f52497-9116-43c8-99f8-3b0b94372874.jpg?v=1785831700","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-multilin-ur6sh-ur-6sh-digital-input-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}