{"product_id":"ge-multilin-ur6lh-ur-6lh-digital-i-o-and-control-module","title":"GE Multilin UR6LH UR-6LH Digital I\/O and Control Module","description":"\u003ch2\u003eGE Multilin UR6LH UR-6LH Digital I\/O and Control Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for digital contact acquisition and relay output execution in General Electric Multilin Universal Relay platforms, the \u003cstrong\u003eGE Multilin UR-6LH\u003c\/strong\u003e (\u003cstrong\u003eUR6LH\u003c\/strong\u003e Digital I\/O and Control Module) provides direct physical\/electrical execution for protection and control circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR6LH \/ UR-6LH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15 cm L x 18 cm W x 4 cm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eModule power supplied through UR chassis backplane; exact consumption depends on relay configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O and Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003eHigh-density digital contact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003eHigh-speed electromechanical relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 to 250 VDC \/ 110 to 230 VAC configurable threshold options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Output Rating\u003c\/td\u003e\n\u003ctd\u003e30 A make for 0.2 s, 8 A continuous at 250 VAC \/ 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, Modbus RTU\/TCP, DNP 3.0 via UR CPU\/Mainframe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Interface\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP Deterministic Networks and Industrial Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe UR6LH module operates as a plug-in I\/O component within the GE Multilin Universal Relay architecture. The module interfaces with the relay CPU through the internal chassis backplane and transfers digital status information for trip logic, interlocking, and control sequences.\u003c\/p\u003e\n\u003cp\u003eThe module design supports industrial control requirements through high-density contact inputs, relay output switching, optical isolation, and continuous self-diagnostic monitoring. The hardware architecture allows integration into GE Multilin protective relay systems including C60, L90, T60, and B30 configurations.\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility and configuration management are handled through the EnerVista UR software environment. Module operation depends on the installed UR firmware revision and host relay configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the UR6LH module designed for hot-swap installation?\u003cbr\u003eA: The UR6LH is a modular plug-in card designed for GE Multilin UR chassis installation. Hot-swap operation depends on the specific UR relay model, chassis configuration, and applicable maintenance procedure.\u003c\/p\u003e\n\u003cp\u003eQ: How are field signals isolated from internal relay processing circuits?\u003cbr\u003eA: The module uses optical isolation methods to separate external contact circuits from internal processing electronics and reduce the effects of EMI and transient disturbances.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication functions are provided directly by the UR6LH module?\u003cbr\u003eA: The UR6LH provides physical digital I\/O functions. Network communication protocols such as IEC 61850, Modbus RTU\/TCP, and DNP 3.0 are handled through the UR CPU and mainframe system.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the UR6LH module only in compatible GE Multilin Universal Relay chassis slots. Verify chassis power isolation before insertion or removal of the plug-in card.\u003c\/p\u003e\n\u003cp\u003eConnect field wiring according to the relay terminal assignment documentation. Separate low-level signal wiring from high-energy switching conductors to reduce electrical interference. Maintain proper shield termination and grounding practices for installed control cables.\u003c\/p\u003e\n\u003cp\u003eConfirm contact input voltage compatibility and relay output load requirements before energizing field circuits. After installation, verify module recognition, I\/O status indication, and diagnostic information through the EnerVista UR software interface.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44503138959448,"sku":"UR6LH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/UR6LV2_8a5ccd11-8929-49bd-8cc3-e44b405cbfae.jpg?v=1785920008","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-multilin-ur6lh-ur-6lh-digital-i-o-and-control-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}