{"product_id":"ge-multilin-ur5dh-ur-5dh-transducer-i-o-module","title":"GE Multilin UR5DH UR-5DH Transducer I\/O Module","description":"\u003ch2\u003eGE Multilin UR5DH UR-5DH Transducer I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin UR-5DH\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eUR-5DH\u003c\/strong\u003e Transducer I\/O Module, operates as a dedicated hardware component for RTD temperature acquisition and DC milliamp signal transmission within GE Universal Relay (UR) Series protection platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR-5DH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE Multilin \/ GE Grid Solutions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eFits GE Universal Relay 19-inch 4U\/8U chassis expansion slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTransducer I\/O Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported RTD Types\u003c\/td\u003e\n\u003ctd\u003e100 Ohm Platinum (Pt100), 120 Ohm Nickel (Ni120), 100 Ohm Nickel (Ni100), 10 Ohm Copper (Cu10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC mA Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC mA Output Range\u003c\/td\u003e\n\u003ctd\u003eProgrammable 0-1 mA, 0-5 mA, 0-10 mA, 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic \/ optical isolation per channel and system ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eUR Series relay expansion slot installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Option\u003c\/td\u003e\n\u003ctd\u003eConformal coating available for harsh substation environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network and I\/O Scaling Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe UR-5DH module provides programmable transducer processing within the GE Universal Relay architecture. The four RTD input channels acquire resistance values directly from field temperature sensors connected to transformer windings, motor stators, bearing assemblies, or ambient measurement points.\u003c\/p\u003e\n\u003cp\u003eThe four DC milliamp outputs convert internal relay measurements into proportional analog signals for connection to legacy SCADA systems, RTUs, DCS input cards, or panel instrumentation. The module supports configurable output scaling through GE EnerVista UR Setup software.\u003c\/p\u003e\n\u003cp\u003eThe module architecture supports I\/O density scaling within the UR relay platform by adding dedicated analog acquisition and output channels without external signal conversion hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the UR-5DH require external RTD transmitters for temperature measurement?\u003cbr\u003eA: No. The module accepts direct RTD resistance inputs from compatible field sensors and transfers the measured values into the relay thermal monitoring functions.\u003c\/p\u003e\n\u003cp\u003eQ: Are the DC milliamp outputs electrically isolated?\u003cbr\u003eA: Yes. The module provides galvanic and optical isolation between channels and the system ground according to the module design specifications.\u003c\/p\u003e\n\u003cp\u003eQ: Can the analog outputs be configured for different current ranges?\u003cbr\u003eA: Yes. The DC milliamp outputs are programmable for ranges including 0-1 mA, 0-5 mA, 0-10 mA, 0-20 mA, and 4-20 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the UR-5DH module into the designated expansion slot of the GE Universal Relay chassis while observing the relay installation procedure.\u003c\/p\u003e\n\u003cp\u003eRTD field wiring should use appropriate instrumentation cable routing practices. Keep sensor wiring separated from high-current power conductors to reduce electromagnetic interference. Shielded cable termination should follow the grounding requirements defined for the connected relay system.\u003c\/p\u003e\n\u003cp\u003eVerify terminal connections for RTD polarity, sensor type configuration, and output loop wiring before energizing the module. Configure RTD parameters and analog output scaling through EnerVista UR Setup software after hardware installation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44503126999128,"sku":"UR5DH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/UR5DH_1f826607-6b70-4add-872a-cc18e05e4f6f.jpg?v=1785919549","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-multilin-ur5dh-ur-5dh-transducer-i-o-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}