{"product_id":"ge-multilin-mifiipi11e10hi00-mif-ii-feeder-protection-relay","title":"GE Multilin MIFIIPI11E10HI00 MIF II Feeder Protection Relay","description":"\u003ch2\u003eGE Multilin MIFIIPI11E10HI00 MIF II Feeder Protection Relay\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin MIFIIPI11E10HI00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMIF II\u003c\/strong\u003e Feeder Protection Relay, operates as a dedicated hardware component for feeder current protection and monitoring within GE Multilin MIF II protection platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMIFIIPI11E10HI00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact draw-out \/ panel mount enclosure; dimensions not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMultilin MIF II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Function\u003c\/td\u003e\n\u003ctd\u003eFeeder \/ Overcurrent Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e1 A \/ 5 A selectable phase current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Power Supply\u003c\/td\u003e\n\u003ctd\u003e88-300 VDC \/ 88-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485 serial communication with Modbus RTU protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Interface\u003c\/td\u003e\n\u003ctd\u003eFront panel LCD with LED status indicators and keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDraw-out \/ panel mount compact case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003ePhase overcurrent, earth fault, thermal overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Capability\u003c\/td\u003e\n\u003ctd\u003eRMS phase and neutral current measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Recording\u003c\/td\u003e\n\u003ctd\u003eTime-stamped event and fault current recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eContinuous hardware and software integrity monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe GE Multilin MIF II platform uses embedded microprocessor-based protection logic with configurable firmware functions for feeder monitoring and protection execution. The MIFIIPI11E10HI00 provides RS485 Modbus RTU communication for SCADA and DCS integration rather than Ethernet-based deterministic industrial networks. Firmware compatibility is managed through the MIF II hardware and software configuration environment, allowing protection parameters, monitoring functions, and relay settings to remain aligned with the installed device configuration.\u003c\/p\u003e\n\u003cp\u003eThe relay supports configurable digital inputs and programmable output contacts for electrical control sequences. The selectable 1 A and 5 A CT input configuration allows adaptation to different current transformer secondary ratings in feeder protection circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the MIFIIPI11E10HI00 support hot-swap replacement?\u003cbr\u003eA: The available technical documentation does not specify hot-swap operation. Replacement should follow standard relay isolation procedures, including control power removal and verification of safe electrical conditions before module removal.\u003c\/p\u003e\n\u003cp\u003eQ: What communication protocol is available for system integration?\u003cbr\u003eA: The relay provides an RS485 serial interface using Modbus RTU protocol for connection with SCADA and DCS monitoring systems.\u003c\/p\u003e\n\u003cp\u003eQ: What current input ratings are supported by the protection relay?\u003cbr\u003eA: The unit supports selectable 1 A and 5 A phase current inputs for connection to compatible CT secondary circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the relay in a suitable panel enclosure with mechanical support for the draw-out mounting arrangement.\u003c\/li\u003e\n\u003cli\u003eVerify auxiliary power supply wiring before energizing. The HI power supply accepts 88-300 VDC or 88-264 VAC control power ranges.\u003c\/li\u003e\n\u003cli\u003eUse properly shielded communication wiring for the RS485 Modbus RTU interface and terminate the network according to RS485 installation practice.\u003c\/li\u003e\n\u003cli\u003eSeparate CT signal wiring from high-current power conductors to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConfirm phase CT polarity and grounding connections before enabling protection functions.\u003c\/li\u003e\n\u003cli\u003eVerify programmable output relay wiring according to the external trip and control circuit requirements.\u003c\/li\u003e\n\u003cli\u003ePerform relay self-diagnostic checks and confirm protection settings after installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44547767074904,"sku":"MIFIIPI11E10HI00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MIFIIPI55E10HI00.jpg?v=1786353186","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-multilin-mifiipi11e10hi00-mif-ii-feeder-protection-relay","provider":"IndustriaX Limited","version":"1.0","type":"link"}