{"product_id":"ge-multilin-g60-generator-protection-system","title":"GE Multilin G60 Generator Protection System","description":"\u003ch2\u003eGE Multilin G60 Generator Protection System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin G60\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eG60\u003c\/strong\u003e Generator Protection System, operates as a dedicated hardware component for generator protection, measurement, automation, and fault recording within Universal Relay (UR) platforms. The unit executes electrical protection functions through CT, VT, I\/O, and communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eG60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mount, 4U height chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eGenerator differential, stator earth fault, loss of field, volts per Hertz, reverse power, unbalanced current, distance, overcurrent, and frequency protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz \/ 60 Hz, frequency tracking range 3 Hz to 90 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Secondary Inputs\u003c\/td\u003e\n\u003ctd\u003e1 A or 5 A nominal, software configurable per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT Secondary Inputs\u003c\/td\u003e\n\u003ctd\u003e50 V to 240 V AC nominal phase-to-neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Options\u003c\/td\u003e\n\u003ctd\u003eHI Range: 88-300 VDC \/ 88-265 VAC; LO Range: 24-48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs \/ Outputs\u003c\/td\u003e\n\u003ctd\u003eScalable modular I\/O cards with Form A, Form C, and SSR outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003eOptional RTD module with Pt100, Ni100, Cu10 and 4-20 mA transducer inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eDual redundant Ethernet ports, 10\/100Base-T RJ45 or 100Base-FX Fiber LC\/ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850 Ed. 1 and Ed. 2, Modbus RTU\/TCP, DNP 3.0, IEC 60870-5-104, IEEE 1588\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent and Fault Recording\u003c\/td\u003e\n\u003ctd\u003eOscillography up to 128 samples\/cycle and Sequence of Events logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet and EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe GE Multilin G60 uses modular industrial communication architecture with dual Ethernet interfaces for network integration. Communication services support IEC 61850, Modbus, DNP 3.0, IEC 60870-5-104, and IEEE 1588 time synchronization. The relay includes embedded synchrophasor measurement capability according to IEEE C37.118 and supports IEC 61850-90-5 synchrophasor multicast operation.\u003c\/p\u003e\n\u003cp\u003eThe device supports PRP network redundancy according to IEC 62439-3 to maintain communication continuity. Ethernet configuration includes RJ45 copper and fiber interface options for substation and generator control network installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of current transformer inputs are supported by the G60?\u003cbr\u003eA: The G60 supports 1 A or 5 A nominal CT secondary inputs with software configuration available for each channel.\u003c\/p\u003e\n\u003cp\u003eQ: Does the G60 support hot-swap replacement of protection modules?\u003cbr\u003eA: The provided data does not specify hot-swap capability. Module replacement procedures must follow the GE Multilin installation manual and approved maintenance practices.\u003c\/p\u003e\n\u003cp\u003eQ: What communication protocols are available for system integration?\u003cbr\u003eA: The G60 supports IEC 61850 Ed. 1 and Ed. 2, Modbus RTU\/TCP, DNP 3.0, IEC 60870-5-104, and IEEE 1588 time synchronization.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the G60 in a compatible 19-inch rack or approved chassis arrangement with correct mechanical support. Verify CT and VT wiring polarity before energizing protection circuits.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication and signal cables according to site grounding practices. Connect cable shields at the designated grounding points to reduce electromagnetic interference. Separate low-level analog signal wiring from high-current power conductors to limit induced noise.\u003c\/p\u003e\n\u003cp\u003eConfirm the selected power supply range before applying auxiliary voltage. Verify Ethernet fiber or copper communication connections, time synchronization wiring, and I\/O terminal assignments during commissioning.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44503141941336,"sku":"G60","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/G60E00HCLF8FH6PM8FP6CU6CW6C.jpg?v=1785920930","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-multilin-g60-generator-protection-system","provider":"IndustriaX Limited","version":"1.0","type":"link"}