{"product_id":"ge-is210hslah1a-high-speed-serial-link-interface-module","title":"GE IS210HSLAH1A High-Speed Serial Link Interface Module","description":"\u003ch2\u003eGE IS210HSLAH1A High-Speed Serial Link Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed serial communication execution in GE Mark VI Speedtronic turbine control system networks, the \u003cstrong\u003eGE IS210HSLAH1A\u003c\/strong\u003e (\u003cstrong\u003eIS210HSLAH1A\u003c\/strong\u003e High-Speed Serial Link Interface Module) provides direct physical and electrical data transfer between turbine control subsystems through RS-485 and RS-422 communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS210\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Speedtronic control system hardware family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSLA\u003c\/td\u003e\n\u003ctd\u003eHigh-Speed Serial Link Interface functional acronym\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH1\u003c\/td\u003e\n\u003ctd\u003eHardware group identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eFunctional revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS210HSLAH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.9 cm x 27.9 cm x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Speed Serial Link Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eHSLA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Revision\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Type\u003c\/td\u003e\n\u003ctd\u003eIS210 Special Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eHigh-speed serial data transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Compatibility\u003c\/td\u003e\n\u003ctd\u003eRS-485, RS-422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 1 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Function\u003c\/td\u003e\n\u003ctd\u003eSerial data exchange between turbine control subsystems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VI Serial Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe IS210HSLAH1A applies GE industrial control communication architecture for deterministic serial data exchange within Mark VI Speedtronic systems. The module supports RS-485 and RS-422 electrical interfaces with communication speeds up to 1 Mbps for subsystem-level data transfer.\u003c\/p\u003e\n\u003cp\u003eThe module design follows GE Mark VI hardware integration requirements, including firmware flash compatibility with the installed control processor revision and backplane bus communication behavior for coordinated I\/O and controller data exchange.\u003c\/p\u003e\n\u003cp\u003eThe HSLA assembly supports I\/O density scaling by providing a dedicated serial communication interface without additional daughterboard components. The special assembly configuration includes no daughterboard, no SCOM grounding terminal, and no metal backplane.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which serial interfaces are supported by the IS210HSLAH1A?\u003cbr\u003eA: The module supports RS-485 and RS-422 electrical communication interfaces for high-speed serial data transfer.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IS210HSLAH1A configured as a hot-swappable module?\u003cbr\u003eA: Hot-swap capability is not specified. Rack power should be removed before module insertion or removal.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum communication data rate of the module?\u003cbr\u003eA: The module supports serial communication data rates up to 1 Mbps.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS210HSLAH1A into the designated GE Mark VI rack position with system power removed. Verify module seating, connector engagement, and grounding connections before restoring power.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication cables for RS-485 and RS-422 signal wiring. Route serial communication cables separately from high-voltage and high-current conductors to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eConfirm that the installed controller firmware and Mark VI configuration database support the module revision. Perform communication diagnostics through the Mark VI HMI after installation to verify serial link integrity.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44382742970456,"sku":"IS210HSLAH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200REBFH1BBA_17905340-fa9b-4f9e-ab98-bc0ff9a53606.jpg?v=1784105474","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-is210hslah1a-high-speed-serial-link-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}