{"product_id":"ge-is2020lvpsg1a-low-voltage-power-supply-module","title":"GE IS2020LVPSG1A Low-Voltage Power Supply Module","description":"\u003ch2\u003eGE IS2020LVPSG1A Low-Voltage Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for regulated DC power distribution in the GE Mark VI\/Mark VIe turbine control system, the \u003cstrong\u003eGE IS2020LVPSG1A\u003c\/strong\u003e (\u003cstrong\u003eIS2020LVPSG1A\u003c\/strong\u003e Low-Voltage Power Supply Module) provides direct electrical conversion and output regulation for processor, I\/O, and auxiliary control modules. The module supplies multiple DC rails through rack backplane integration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS2020LVPSG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e233 x 160 x 18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified; conversion efficiency \u0026gt;=92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLow-Voltage Power Supply Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI \/ Mark VIe Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC (50\/60 Hz) or 120-370 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Input\u003c\/td\u003e\n\u003ctd\u003e28 VDC for rack integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rails\u003c\/td\u003e\n\u003ctd\u003e5 VDC at 20 A, +15 VDC at 5 A, -15 VDC at 5 A, 24 VDC at 10 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eSurge, overload, short-circuit, overvoltage, overtemperature shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvertemperature Shutdown\u003c\/td\u003e\n\u003ctd\u003e105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Power Conversion and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe IS2020LVPSG1A applies GE industrial control power architecture for Mark VI\/Mark VIe systems. The module provides multi-rail DC output distribution through rack integration and supports I\/O density scaling by supplying multiple connected control modules.\u003c\/p\u003e\n\u003cp\u003eThe power supply architecture supports redundant feed configurations for load sharing and failover operation. Backplane bus power distribution maintains regulated voltage delivery between the power module and connected controller hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What DC output voltages are provided by the IS2020LVPSG1A?\u003cbr\u003eA: The module provides 5 VDC, +15 VDC, -15 VDC, and 24 VDC output rails for Mark VI\/Mark VIe control hardware.\u003c\/p\u003e\n\u003cp\u003eQ: What protection functions are integrated into the power supply module?\u003cbr\u003eA: The module includes surge protection, overload protection, short-circuit protection, overvoltage protection, and thermal shutdown functions.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module operate in a redundant power configuration?\u003cbr\u003eA: The supplied data indicates support for dual-feed redundant configurations for failover and load sharing applications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS2020LVPSG1A in the designated GE Mark VI\/Mark VIe rack position and verify mechanical alignment before engaging the backplane connector.\u003c\/p\u003e\n\u003cp\u003eConfirm input voltage range compatibility before energizing the module. Route AC\/DC power wiring separately from low-level analog signal cables to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eCheck output rail measurements during commissioning and verify rack-connected modules receive correct supply voltages. Inspect connectors, grounding paths, and cooling airflow conditions during scheduled maintenance.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44382917591128,"sku":"IS2020LVPSG1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS2020RKPSG3A1.jpg?v=1784109364","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-is2020lvpsg1a-low-voltage-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}