{"product_id":"ge-is200tbais1ced-analog-input-output-terminal-board","title":"GE IS200TBAIS1CED Analog Input\/Output Terminal Board","description":"\u003ch2\u003eGE IS200TBAIS1CED Analog Input\/Output Terminal Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog field signal interfacing in GE Mark VIe control architecture, the \u003cstrong\u003eGE IS200TBAIS1CED\u003c\/strong\u003e (\u003cstrong\u003eIS200TBAIS1C\u003c\/strong\u003e Analog Input\/Output Terminal Board) provides direct physical\/electrical execution between field wiring and controller I\/O processors through conditioned analog input and output channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TBAIS1CED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.16 cm (W) x 33.02 cm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in available data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Mark VIe Control Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSimplex and Triple Modular Redundant (TMR) configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e3 x DC-37 pin connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Handling\u003c\/td\u003e\n\u003ctd\u003eAnalog input signal distribution across R, S, T processors in TMR mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Regulation\u003c\/td\u003e\n\u003ctd\u003eTMR driver current aggregation through precision shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eOnboard ID chip with serial number, revision, and connector information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eCurrent\/voltage input selection through jumper settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003eConfigurable 1 mA or 20 mA input ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark VIeS SIS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VIe TMR Analog Signal Processing and Hardware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBAIS1CED terminal board supports GE Mark VIe distributed control signal architecture by providing analog field termination, signal conditioning, and processor interface functions. In TMR configurations, the board distributes analog input signals to the R, S, and T controller processors to maintain synchronized data acquisition.\u003c\/p\u003e\n\u003cp\u003eThe board uses GE firmware flash compatibility and onboard identification hardware to verify terminal board configuration data, including serial information, revision status, and connector assignments. This ID-based verification supports correct hardware recognition during Mark VIe system configuration.\u003c\/p\u003e\n\u003cp\u003eThe terminal board provides I\/O density scaling within the Mark VIe platform by allowing multiple analog channels to interface with controller processors while maintaining defined signal routing and diagnostic monitoring. Output current monitoring functions detect hardware compatibility conditions and verify output circuit behavior.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What configuration modes are supported by the IS200TBAIS1CED terminal board?\u003cbr\u003eA: The terminal board supports Simplex configuration through the JR1 connector and TMR configuration using JR, JS, and JT connectors.\u003c\/p\u003e\n\u003cp\u003eQ: How does the board identify its hardware configuration?\u003cbr\u003eA: An onboard ID chip stores serial number, revision information, and connector data for hardware identification and compatibility checking.\u003c\/p\u003e\n\u003cp\u003eQ: What analog signal settings can be adjusted on the terminal board?\u003cbr\u003eA: Jumper settings allow configuration of current or voltage input selection, return link options, and supported input ranges including 1 mA and 20 mA settings.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200TBAIS1CED according to GE Mark VIe panel assembly procedures. Confirm terminal board orientation, connector engagement, and field wiring termination before applying control power.\u003c\/p\u003e\n\u003cp\u003eUse shielded instrumentation wiring for analog signal connections where required by the system grounding design. Connect cable shields according to the Mark VIe cabinet grounding scheme and separate low-level analog wiring from high-current switching conductors.\u003c\/p\u003e\n\u003cp\u003eVerify jumper positions for current\/voltage selection and input range configuration before commissioning. Confirm that connector assignments match the configured Simplex or TMR architecture to prevent signal routing errors.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44350067212376,"sku":"IS200TBAIS1CED","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200TBCIH2C.jpg?v=1783587633","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-is200tbais1ced-analog-input-output-terminal-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}