{"product_id":"ge-is200eselh2rrr-exciter-selector-board","title":"GE IS200ESELH2RRR Exciter Selector Board","description":"\u003ch2\u003eGE IS200ESELH2RRR Exciter Selector Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for excitation signal routing in GE Mark VI turbine control systems, the \u003cstrong\u003eGE IS200ESELH2RRR\u003c\/strong\u003e (\u003cstrong\u003eIS200ESELH2RRR\u003c\/strong\u003e Exciter Selector Board) provides direct physical\/electrical execution between turbine control processors and generator field devices through dedicated communication and signal paths.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ESELH2RRR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 x 150 x 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExciter Selector Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI turbine control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eFPGA-based high-speed logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS232, RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Signal Routing\u003c\/h3\u003e\n\u003cp\u003eThe IS200ESELH2RRR uses FPGA-based logic processing to manage excitation signal selection and routing between Mark VI turbine control processors and connected field devices. The communication interfaces support structured data exchange through Ethernet, RS232, and RS485 connections within the turbine control architecture.\u003c\/p\u003e\n\u003cp\u003eThe board operates as a signal coordination component for industrial control networks, maintaining defined communication paths and processing timing for excitation-related data. Its hardware design supports integration with GE Mark VI modular control systems where processor communication and field signal distribution are required.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interfaces are available on the IS200ESELH2RRR?\u003cbr\u003eA: The board provides Ethernet, RS232, and RS485 communication interfaces for connection within the Mark VI control system architecture.\u003c\/p\u003e\n\u003cp\u003eQ: What is the operating voltage requirement of this board?\u003cbr\u003eA: The IS200ESELH2RRR operates with a 24 VDC supply input.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IS200ESELH2RRR designed for standalone operation?\u003cbr\u003eA: No. The board is designed for integration into GE Mark VI turbine control systems and operates as part of the overall excitation control configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200ESELH2RRR according to GE Mark VI rack and panel mounting procedures. Verify the 24 VDC supply polarity and confirm connector alignment before system energization.\u003c\/p\u003e\n\u003cp\u003eUse appropriate shielded communication cables for RS232, RS485, and Ethernet connections where required by the installation environment. Maintain separation between communication wiring and high-current excitation conductors to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eConfirm grounding continuity, mechanical fastening, and cable routing conditions during installation. After replacement, perform system diagnostics and communication verification through the Mark VI control interface before returning the excitation system to service.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44371845644376,"sku":"IS200ESELH2RRR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200ESELH2RRR.jpg?v=1783932267","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-is200eselh2rrr-exciter-selector-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}