{"product_id":"ge-is200aepah1afd-auxiliary-control-and-redundant-power-supply-module","title":"GE IS200AEPAH1AFD Auxiliary Control and Redundant Power Supply Module","description":"\u003ch2\u003eGE IS200AEPAH1AFD Auxiliary Control and Redundant Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for actuator control execution and redundant power interface management in GE Mark VI\/Mark VIe turbine control platforms, the \u003cstrong\u003eGE IS200AEPAH1AFD\u003c\/strong\u003e (\u003cstrong\u003eIS200AEPAH1AFD\u003c\/strong\u003e Auxiliary Control Module) provides direct physical\/electrical execution. The module processes actuator feedback signals, controls output channels, and distributes regulated power rails within the VME-based control architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200AEPAH1AFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Control \/ Redundant Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI \/ Mark VIe Speedtronic turbine control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85-132 VAC \/ 170-265 VAC auto-ranging or 110-150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e+5 VDC, +\/-15 VDC, +24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Rating\u003c\/td\u003e\n\u003ctd\u003e200-250 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit processor, 160 MHz, watchdog timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Outputs\u003c\/td\u003e\n\u003ctd\u003e2 channels, selectable 4-20 mA or +\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition Feedback Inputs\u003c\/td\u003e\n\u003ctd\u003e2 LVDT inputs, 2 potentiometer inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd\u003e14-bit, 0.006% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e4 kHz per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e1 ms feedback-to-output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eSimplex, dual, and triple configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25 x 18 x 2.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified; module output rating 200-250 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eVME rack slot insertion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eOvervoltage, overcurrent, short-circuit, thermal shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VIe Control and Power Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe IS200AEPAH1AFD module uses industrial control architecture features associated with GE Mark VI\/Mark VIe systems, including deterministic control processing, actuator feedback handling, and redundant power distribution. The module supports I\/O density scaling through multiple feedback and output channels while maintaining separated signal paths for actuator regulation.\u003c\/p\u003e\n\u003cp\u003eThe board provides interfaces for LVDT and potentiometer position feedback, with actuator command outputs configurable for current or voltage operation. The onboard watchdog timer monitors processor operation, while protection circuits supervise power and output conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What actuator signals are supported by the IS200AEPAH1AFD module?\u003cbr\u003eA: The module supports two actuator output channels configurable for 4-20 mA or +\/-10 V signals and accepts position feedback from LVDT and potentiometer inputs.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support redundant power configurations?\u003cbr\u003eA: The IS200AEPAH1AFD supports simplex, dual, and triple redundancy configurations within compatible Mark VI\/Mark VIe control architectures.\u003c\/p\u003e\n\u003cp\u003eQ: What type of rack installation is required?\u003cbr\u003eA: The module is installed through a VME rack slot interface and requires proper chassis alignment and connector engagement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in the designated VME rack position with the chassis power removed before insertion or removal. Verify connector seating and mechanical retention before applying system power.\u003c\/p\u003e\n\u003cp\u003eRoute actuator signal wiring separately from high-current power conductors to reduce electrical interference. Use appropriate shielding practices for analog feedback cables, with shield termination following the system grounding design.\u003c\/p\u003e\n\u003cp\u003eVerify input voltage configuration before energizing the module. Confirm actuator feedback polarity, signal scaling, and output channel assignment during commissioning.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44371878183000,"sku":"IS200AEPAH1AFD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200AEPCH2CEC.jpg?v=1783934028","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-is200aepah1afd-auxiliary-control-and-redundant-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}