{"product_id":"ge-is200aebeg1a-mark-vi-analog-ethernet-board","title":"GE IS200AEBEG1A Mark VI Analog \u0026 Ethernet Board","description":"\u003ch2\u003eGE IS200AEBEG1A Mark VI Analog \u0026amp; Ethernet Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200AEBEG1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200AEBEG1A\u003c\/strong\u003e Analog \u0026amp; Ethernet Board, operates as a dedicated hardware component for analog signal acquisition and Ethernet communication execution within the GE Mark VI Speedtronic Turbine Control System.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200AEBEG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 x 60 x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 50 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog \u0026amp; Ethernet Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eVME-style plug-in PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 differential channels, 4-20 mA input support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003eConfigurable output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC via Mark VI backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet IONet protocol, Mark VI backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eModule diagnostics and LED fault indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ Ethernet Deterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe IS200AEBEG1A provides analog signal conditioning and Ethernet-based communication within the Mark VI control architecture. The board converts field instrumentation signals, including 4-20 mA transmitter inputs, into processed data for controller applications through the Mark VI backplane.\u003c\/p\u003e\n\u003cp\u003eThe module supports GE IONet communication paths for deterministic data exchange between field interface hardware and control processors. Firmware flash compatibility and configured hardware addressing allow integration with approved Mark VI application software environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What analog signals can the IS200AEBEG1A process?\u003cbr\u003eA: The board supports analog acquisition functions including 4-20 mA differential input channels and signal conditioning for compatible field instrumentation.\u003c\/p\u003e\n\u003cp\u003eQ: How does the IS200AEBEG1A communicate with the Mark VI controller?\u003cbr\u003eA: The board communicates through Ethernet IONet protocol and the Mark VI backplane interface for controller data exchange.\u003c\/p\u003e\n\u003cp\u003eQ: What power source is required for the IS200AEBEG1A?\u003cbr\u003eA: The module receives operating power through the Mark VI backplane with a nominal 24 VDC supply arrangement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200AEBEG1A into the assigned Mark VI VME-style rack position and confirm correct mechanical alignment with the backplane connector. Verify cabinet grounding continuity before applying system power.\u003c\/p\u003e\n\u003cp\u003eRoute analog field wiring separately from high-voltage and high-current conductors. Use shielded cable practices for sensitive analog channels and terminate shields according to the turbine control cabinet grounding scheme.\u003c\/p\u003e\n\u003cp\u003eBefore board replacement or firmware loading, verify the installed hardware revision, I\/O configuration, and compatible Mark VI application parameters. Confirm analog channel assignments and Ethernet network addressing before returning the control system to service.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44377129255000,"sku":"IS200AEBEG1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/general-electric-is200aeadh4a-input-terminal-board-uyfat3pxjlm.png?v=1758525340","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-is200aebeg1a-mark-vi-analog-ethernet-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}