{"product_id":"ge-fanuc-ic697bem731p-genius-bus-controller-module","title":"GE Fanuc IC697BEM731P Genius Bus Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC697BEM731P is a dedicated Genius Bus Controller Module (BCM) designed for integration within the Series 90-70 PLC platform. This module functions as a high-speed communication bridge, linking the PLC backplane to the Genius I\/O network. It is engineered to support complex industrial automation tasks, providing reliable data exchange and peer-to-peer communication capabilities in environments such as chemical processing, power generation, and large-scale manufacturing.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Capacity:\u003c\/strong\u003e Supports up to 30 drops per channel, allowing for scalable I\/O expansion across the Genius bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAsynchronous Scanning:\u003c\/strong\u003e Optimizes CPU performance by managing I\/O data transfers independently once per scan cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Interface:\u003c\/strong\u003e Equipped with an integrated Handheld Monitor (HHM) serial port for direct system diagnostics, status monitoring, and fault troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Availability:\u003c\/strong\u003e Fully compatible with redundant CPU, cable, and I\/O block configurations to maintain system integrity in mission-critical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Communication:\u003c\/strong\u003e Facilitates directed communication via CPU service requests and supports global data transfers for LAN integration with other bus controllers and PCIMs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Always disconnect power from the Series 90-70 rack before inserting or removing the module to prevent electrical damage or system faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e The module occupies a single slot in the Series 90-70 chassis. Ensure the module is fully seated and the locking levers are secured.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the rack is properly grounded to mitigate EMI\/RFI interference, which is critical for stable Genius bus communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Use shielded communication cables for the Genius bus. Route signal cables away from high-voltage power lines to prevent signal degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Initial setup requires compatible MS-DOS or Windows-based programming software to define bus parameters and node addresses.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697BEM731P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries 90-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eGenius Bus Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrops per Channel\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Port\u003c\/td\u003e\n\u003ctd\u003e1 x HHM Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e153.5 kBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.3 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Occupancy\u003c\/td\u003e\n\u003ctd\u003e1 Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC697BEM731P?\u003c\/h3\u003e\u003cp\u003eThis module acts as the interface between the Series 90-70 PLC and the Genius I\/O network, enabling the PLC to control and monitor remote I\/O blocks across the plant floor.\u003c\/p\u003e\u003ch3\u003eDoes this module support redundant systems?\u003c\/h3\u003e\u003cp\u003eYes, the IC697BEM731P is designed to support redundant configurations, including redundant cables, blocks, and CPUs, to ensure continuous operation in critical control loops.\u003c\/p\u003e\u003ch3\u003eHow do I perform diagnostics on this module?\u003c\/h3\u003e\u003cp\u003eThe module features a dedicated HHM (Handheld Monitor) serial port, which allows technicians to connect a diagnostic device for real-time status updates and fault analysis.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":44644674601048,"sku":"IC697BEM731P","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_928f8110-9110-4f91-a688-f9393e4a63eb.jpg?v=1787423569","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-fanuc-ic697bem731p-genius-bus-controller-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}