{"product_id":"ge-ds200vpblg2a-vme-processor-bus-master-board","title":"GE DS200VPBLG2A VME Processor\/Bus Master Board","description":"\u003ch2\u003eGE DS200VPBLG2A VME Processor\/Bus Master Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200VPBLG2A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200VPBLG2A\u003c\/strong\u003e VME Processor\/Bus Master Board, operates as a dedicated hardware component for VMEbus traffic management and processor-level data exchange within the GE Mark V SpeedTronic Control System.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200VPBLG2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVME Processor \/ Bus Master Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eMark V SpeedTronic Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Architecture\u003c\/td\u003e\n\u003ctd\u003eStandard VMEbus interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision Level\u003c\/td\u003e\n\u003ctd\u003eGroup 2 Functional Revision A (G2A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVME Connectors\u003c\/td\u003e\n\u003ctd\u003eEight VME connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExciter Connector\u003c\/td\u003e\n\u003ctd\u003e34-Pin ribbon connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003e12-Pin terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eHigh-density rack-mounted PCB module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Reference\u003c\/td\u003e\n\u003ctd\u003eGEI-100227\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic VMEbus Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe DS200VPBLG2A board operates as a VME processor and bus master interface inside the Mark V SpeedTronic rack architecture. The module manages VMEbus transactions between processor resources and installed I\/O boards through the backplane connection. Hardware configuration depends on the installed firmware revision and compatible Mark V rack components. The board provides controlled data transfer paths for system task execution, I\/O communication, and rack-level processing coordination.\u003c\/p\u003e\n\u003cp\u003eThe module supports firmware flash compatibility requirements associated with the Mark V platform. Firmware revision matching must be verified before replacement or rack integration to maintain processor communication behavior and VMEbus addressing compatibility.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the DS200VPBLG2A board?\u003cbr\u003eA: The DS200VPBLG2A functions as a VME Processor\/Bus Master Board, controlling VMEbus communication and coordinating data exchange between processor functions and connected I\/O boards.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DS200VPBLG2A use standard VMEbus connections?\u003cbr\u003eA: Yes. The board is designed for integration into a Mark V rack using VMEbus backplane connectors and associated front-panel interfaces.\u003c\/p\u003e\n\u003cp\u003eQ: Are firmware revisions interchangeable between DS200VPBLG2A boards?\u003cbr\u003eA: Firmware compatibility depends on the Mark V system configuration and installed hardware revision. Matching firmware and board revision requirements must be confirmed before installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DS200VPBLG2A only in the designated Mark V SpeedTronic rack position specified by the system configuration documentation.\u003c\/li\u003e\n\u003cli\u003eVerify VME backplane connector alignment before insertion to prevent mechanical damage to PCB edge contacts.\u003c\/li\u003e\n\u003cli\u003eConfirm power isolation before removing or installing the board inside the control rack.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing for the 34-Pin ribbon connector and 12-Pin terminal block wiring to prevent mechanical stress and signal interference.\u003c\/li\u003e\n\u003cli\u003eInspect connector contacts, PCB surfaces, and rack backplane interfaces before installation.\u003c\/li\u003e\n\u003cli\u003eFollow applicable grounding and shielding practices for industrial control cabinet wiring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44484692181080,"sku":"DS200VPBLG2A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/GE-DS200VPBLG1A-1oyrrqh31ct.png?v=1756197273","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-ds200vpblg2a-vme-processor-bus-master-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}