{"product_id":"ge-ds200tcpdg2bec-mark-v-power-distribution-board","title":"GE DS200TCPDG2BEC Mark V Power Distribution Board","description":"\u003ch2\u003eGE DS200TCPDG2BEC Mark V Power Distribution Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for managing regulated DC power routing with integrated protection and diagnostics in GE Mark V Speedtronic systems, the \u003cstrong\u003eGE DS200TCPDG2BEC\u003c\/strong\u003e (\u003cstrong\u003eDS200TCPD\u003c\/strong\u003e Power Distribution Module) provides direct physical\/electrical execution. As a core power routing component within the Speedtronic platform, this board establishes clean voltage delivery pathways across system backplane nodes, processing cards, and field relay interfaces. It features dedicated onboard bus filtering and real-time LED diagnostics to ensure continuous operational integrity for heavy-duty gas and steam turbine control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCPDG2BEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive distribution node (circuit dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Mark V Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Type\u003c\/td\u003e\n\u003ctd\u003ePower Distribution Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e125 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e12 isolated DC circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e10 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic circuit breakers, fuse backup, LED fault indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eVME rack compatible slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCPDG2BEC incorporates low-impedance copper bus traces designed to handle rapid transient current shifts without compromising backplane bus communication velocity across adjacent VME control slots. By regulating power lines feeding the processor, relay, and analog I\/O modules (such as the DS200TCRAG1A and DS200TCQCG1B), it prevents localized voltage sags that could interfere with high-speed deterministic control loops. Furthermore, its hardware topology maintains passive power bus stability regardless of the firmware flash compatibility status or revision levels running on downstream microprocessor cards, isolating hardware power delivery from software execution states.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the onboard LEDs on the DS200TCPDG2BEC?\u003c\/p\u003e\n\u003cp\u003eA: The onboard LEDs provide visual indication of power distribution state and fault conditions. A blown fuse or tripped electronic circuit breaker triggers an immediate status change, allowing quick visual diagnostics during maintenance or troubleshooting.\u003c\/p\u003e\n\u003cp\u003eQ: Does replacing the DS200TCPDG2BEC require complete system de-energization?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Because the DS200TCPDG2BEC distributes core 125 VDC control power to primary processing and I\/O modules, power must be completely isolated from the distribution rack prior to removing or installing the board to avoid arc flash risks and control processor reset.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Clearance \u0026amp; Mounting:\u003c\/strong\u003e Ensure the VME rack slot is cleared of debris before insertion. Align the card edge connectors precisely with the rack backplane guide rails, applying steady, firm pressure to seat the multi-pin DIN connectors without bending pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring \u0026amp; Cable Connections:\u003c\/strong\u003e Verify that all high-current DC output lines are properly terminated with correct ring terminals or secure screw clamps. Route input and output cables separately from low-voltage signal wires to prevent inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Securely bond the board ground connection to the cabinet central chassis ground point. Ensure low-resistance metal-to-metal contact to maintain full noise suppression and surge protection functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing \u0026amp; Overcurrent Protection:\u003c\/strong\u003e Inspect all onboard fuses prior to powering up the system. Ensure replacement fuses strictly match the factory current and voltage ratings specified by General Electric for Mark V power distribution circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44473012682840,"sku":"DS200TCPDG2BEC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200TCPDG2BEC.jpg?v=1785235020","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-ds200tcpdg2bec-mark-v-power-distribution-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}