{"product_id":"ge-ds200tccbg8b-common-extended-analog-i-o-board","title":"GE DS200TCCBG8B Common Extended Analog I\/O Board","description":"\u003ch2\u003eGE DS200TCCBG8B Common Extended Analog I\/O Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200TCCBG8B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TCCBG8B\u003c\/strong\u003e Common Extended Analog I\/O Board, operates as a dedicated hardware component for analog signal conditioning and acquisition within the Speedtronic Mark V \/ Mark V LM Turbine Control system. It processes external current, voltage, and temperature-related signals through the Mark V I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCCBG8B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommon Extended Analog I\/O Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System Series\u003c\/td\u003e\n\u003ctd\u003eSpeedtronic Mark V \/ Mark V LM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Abbreviation\u003c\/td\u003e\n\u003ctd\u003eTCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Location\u003c\/td\u003e\n\u003ctd\u003eR5 Core, Slot 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eAnalog input conditioning and scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-1 mA, RTD, line current, generator and bus voltage inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Interface\u003c\/td\u003e\n\u003ctd\u003e3PL connector and COREBUS communication path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Memory\u003c\/td\u003e\n\u003ctd\u003eTwo configurable EEPROM devices required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCCBG8B provides analog signal processing functions within the GE Speedtronic Mark V LM platform. The board scales and conditions auxiliary analog inputs received from terminal and expansion interface boards before transferring processed data through the COREBUS network.\u003c\/p\u003e\n\u003cp\u003eThe board performs electrical processing of PT and CT measurement signals for generator monitoring calculations, including megawatt (MW), megavar (MVAR), power factor, and phase voltage\/current values. The conditioned information is routed to the Turbine Communication Board (STCA) and the primary I\/O Engine through the 3PL interface.\u003c\/p\u003e\n\u003cp\u003eThe Mark V architecture uses deterministic internal communication paths for controller synchronization. The DS200TCCBG8B firmware configuration is dependent on installed EEPROM devices, which contain application-specific board operating parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What signal types can the DS200TCCBG8B process?\u003cbr\u003eA: The board processes analog signals including 4-20 mA inputs, 0-1 mA inputs, RTD inputs, line current measurements, and generator or bus voltage signals.\u003c\/p\u003e\n\u003cp\u003eQ: What is the function of the programmable EEPROM devices on this board?\u003cbr\u003eA: The EEPROM devices store board configuration data required for operation within the Speedtronic Mark V \/ Mark V LM control system.\u003c\/p\u003e\n\u003cp\u003eQ: How does the DS200TCCBG8B communicate with the turbine control system?\u003cbr\u003eA: The board transfers conditioned analog data through the 3PL connector and COREBUS communication network to the Turbine Communication Board and I\/O Engine.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DS200TCCBG8B only in the designated R5 core slot position within the Mark V \/ Mark V LM control cabinet.\u003c\/li\u003e\n\u003cli\u003eVerify the installed EEPROM configuration matches the application-specific turbine control software setup before energizing the system.\u003c\/li\u003e\n\u003cli\u003eUse appropriate grounding methods for analog signal shields to reduce electrical noise and measurement interference.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level analog signal wiring from high-current power conductors and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm connector seating and backplane engagement before system startup.\u003c\/li\u003e\n\u003cli\u003eFollow GEH-6153 installation and maintenance documentation for board replacement procedures and configuration verification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44484858118232,"sku":"DS200TCCBG8B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200TCCBG8BED.jpg?v=1785489963","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-ds200tccbg8b-common-extended-analog-i-o-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}