{"product_id":"ge-ds200tccbg3b-common-extended-analog-i-o-board","title":"GE DS200TCCBG3B Common Extended Analog I\/O Board","description":"\u003ch2\u003eGE DS200TCCBG3B Common Extended Analog I\/O Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for extended analog signal acquisition and conditioning in GE Speedtronic Mark V control systems, the \u003cstrong\u003eGE DS200TCCBG3B\u003c\/strong\u003e (\u003cstrong\u003eDS200TCCBG3B\u003c\/strong\u003e Common Extended Analog I\/O Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCCBG3B is provided as a fixed GE Speedtronic Mark V hardware part number. Available documentation identifies the complete ordering code but does not define independent field-selectable suffix options.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Element\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200\u003c\/td\u003e\n\u003ctd\u003eGE Speedtronic Mark V board family identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTCCB\u003c\/td\u003e\n\u003ctd\u003eFunctional acronym for Common Extended Analog I\/O Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3B\u003c\/td\u003e\n\u003ctd\u003eBoard group and functional revision identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC2000\u003c\/td\u003e\n\u003ctd\u003eAnalog expansion board designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCCBG3B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSpeedtronic Mark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Type\u003c\/td\u003e\n\u003ctd\u003eCommon Extended Analog I\/O Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eTCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Description\u003c\/td\u003e\n\u003ctd\u003eExtended Analog I\/O Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel 80196 onboard microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eMultiple EPROM \/ PROM modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e2 x 50-pin connectors and 5 x 34-pin ribbon connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Indicator\u003c\/td\u003e\n\u003ctd\u003e1 x green edge-visible diagnostic LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eStandard conformal industrial coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Revision\u003c\/td\u003e\n\u003ctd\u003eRevision B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Mark V Control Architecture\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCCBG3B operates as an analog expansion interface within the GE Speedtronic Mark V turbine control platform. The board extends analog I\/O capacity by providing additional signal acquisition paths and conditioning circuits between field devices and the Mark V control processor architecture.\u003c\/p\u003e\n\u003cp\u003eThe onboard Intel 80196 microprocessor manages local board functions, while EPROM and PROM memory devices store board-specific operating firmware. Firmware flash compatibility is determined by the installed Mark V hardware revision and configured control system software.\u003c\/p\u003e\n\u003cp\u003eThe board communicates through dedicated ribbon cable connections using the Mark V internal control architecture. Proper I\/O density scaling depends on the installed rack configuration and available system interface capacity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DS200TCCBG3B operate as a standalone controller?\u003cbr\u003eA: No. The board functions as an analog I\/O expansion interface and operates as part of the GE Speedtronic Mark V control system.\u003c\/p\u003e\n\u003cp\u003eQ: What processor is installed on the DS200TCCBG3B?\u003cbr\u003eA: The board contains an Intel 80196 onboard microprocessor for local board-level processing functions.\u003c\/p\u003e\n\u003cp\u003eQ: Is the DS200TCCBG3B hot-swappable during system operation?\u003cbr\u003eA: Available documentation does not specify hot-swap capability. Power removal and system shutdown procedures should be followed before board replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DS200TCCBG3B in the designated GE Speedtronic Mark V rack position according to the applicable GE hardware installation manual.\u003c\/p\u003e\n\u003cp\u003eVerify all ribbon cable connections before energizing the control system. Inspect connector alignment and ensure that cable routing maintains separation from high-current power conductors to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eMaintain PCB handling procedures to prevent electrostatic discharge damage to processor and memory components. Confirm board revision compatibility before installation into an existing Mark V configuration.\u003c\/p\u003e\n\u003cp\u003eConnect field signal wiring with appropriate shielding and grounding practices. Avoid routing low-level analog signal conductors parallel to high-voltage switching circuits.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44484744544344,"sku":"DS200TCCBG3B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200TCCBG8B.jpg?v=1785486993","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-ds200tccbg3b-common-extended-analog-i-o-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}