{"product_id":"ge-ds200tbqcg1abb-terminal-board-assembly","title":"GE DS200TBQCG1ABB Terminal Board Assembly","description":"\u003ch2\u003eGE DS200TBQCG1ABB Terminal Board Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200TBQCG1ABB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TBQC\u003c\/strong\u003e Terminal Board Assembly, operates as a dedicated hardware component for analog and digital field signal termination within the GE Mark V LM turbine control system. It provides physical wiring interfaces for I\/O signals, actuator circuits, and sensor connections.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TBQCG1ABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Milliamp I\/O Termination Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V LM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eTBQC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types Supported\u003c\/td\u003e\n\u003ctd\u003eAnalog input signals, digital signals, trip circuit signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Current\u003c\/td\u003e\n\u003ctd\u003e0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Voltage Range\u003c\/td\u003e\n\u003ctd\u003e+5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Lead Resistance\u003c\/td\u003e\n\u003ctd\u003e15 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eMulti-level screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e2500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive termination board, no onboard processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic I\/O Interface and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe DS200TBQCG1ABB is a passive termination assembly within the GE Mark V LM control platform. It provides structured field wiring connections for analog milliamp signals, digital inputs, and turbine auxiliary circuits. The board transfers field signals to controller and I\/O processing modules without executing application logic.\u003c\/p\u003e\n\u003cp\u003eThe terminal module supports analog signal interface functions including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e12-channel analog termination capability\u003c\/li\u003e\n\u003cli\u003e0-20 mA signal routing\u003c\/li\u003e\n\u003cli\u003eField device connection through screw terminals\u003c\/li\u003e\n\u003cli\u003eSignal transfer between external instruments and Mark V controller electronics\u003c\/li\u003e\n\u003cli\u003eCompatibility with connected processor and I\/O modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Control Network and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eAs a GE industrial control component, the TBQC module operates as part of the Mark V LM I\/O architecture. The module supports I\/O density scaling through organized termination of multiple field channels while maintaining defined wiring separation between signal groups.\u003c\/p\u003e\n\u003cp\u003eThe terminal interface does not provide Ethernet, VMEbus, or independent communication processing. Data acquisition and control execution are performed by connected Mark V controller modules. Proper firmware and I\/O configuration compatibility are required at the controller level for correct channel operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DS200TBQCG1ABB contain a processor or configurable firmware?\u003cbr\u003eA: No. The DS200TBQCG1ABB is a passive terminal board. Processing functions are performed by connected Mark V controller and I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: What type of signals can be connected through the TBQC module?\u003cbr\u003eA: The module supports analog milliamp signals, digital field connections, and turbine control related wiring interfaces according to the Mark V LM configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Does the terminal board require independent power input?\u003cbr\u003eA: No. The board functions as a passive signal termination interface and does not contain independent power conversion circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DS200TBQCG1ABB in the designated Mark V LM rack position and verify correct mechanical seating before connecting field wiring.\u003c\/p\u003e\n\u003cp\u003eRoute analog signal cables separately from high-current power conductors and trip circuit wiring to reduce electromagnetic interference. Maintain proper cable identification and terminal labeling during installation.\u003c\/p\u003e\n\u003cp\u003eConnect cable shields according to the system grounding design. Check screw terminal tightness and inspect wiring condition during commissioning and maintenance activities.\u003c\/p\u003e\n\u003cp\u003eVerify channel assignments, controller configuration, and connected I\/O module compatibility before applying field signals.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44437360017496,"sku":"DS200TBQCG1ABB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200TBQCG1ABB.jpg?v=1784797423","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-ds200tbqcg1abb-terminal-board-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}