{"product_id":"ge-ds200lrpag1a-mark-v-relay-output-board","title":"GE DS200LRPAG1A Mark V Relay Output Board","description":"\u003ch2\u003eGE DS200LRPAG1A Mark V Relay Output Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200LRPAG1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200LRPAG1A\u003c\/strong\u003e Relay Output Board, operates as a dedicated hardware component for electromechanical relay signal execution within the GE Mark V SpeedTronic turbine control system. The board converts low-level control signals into isolated field relay contact outputs for external switching circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200LRPAG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V SpeedTronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Type\u003c\/td\u003e\n\u003ctd\u003eRelay Output \/ Interface Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLine Protection Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eLRPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eElectromechanical relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003eForm C \/ SPDT or Form A \/ SPST dependent on jumper configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e125 VDC \/ 250 VAC nominal switching capacity dependent on load profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED indicators for relay output channel status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eMulti-pin ribbon cable header connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eCard rack or panel-mounted via insulated standoffs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eNormal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Revision\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Backplane and Drive Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe DS200LRPAG1A operates within the GE Mark V control architecture through ribbon cable header interfaces connected to the control core. Logic-level commands received from the processor section activate relay driver circuits, which energize the corresponding relay coils.\u003c\/p\u003e\n\u003cp\u003eThe board supports industrial control execution through electromechanical contact switching. Relay outputs provide physical isolation between control electronics and external field circuits connected to actuators, alarms, contactors, and interlock devices.\u003c\/p\u003e\n\u003cp\u003eThe GE Mark V hardware platform uses modular rack communication and interface cards. The DS200LRPAG1A implementation requires correct firmware and hardware revision compatibility when installed in existing control configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DS200LRPAG1A provide direct solid-state field outputs?\u003cbr\u003eA: No. The board provides electromechanical relay contact outputs. The relay contacts change state after the internal relay coil is energized by the control signal interface.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic method is available for relay channel verification?\u003cbr\u003eA: Each relay channel includes an LED status indicator that allows visual confirmation of relay energization during commissioning and maintenance procedures.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DS200LRPAG1A be installed without checking rack compatibility?\u003cbr\u003eA: No. Installation requires verification of Mark V rack configuration, connector alignment, revision compatibility, and field wiring requirements before replacement or commissioning.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the card rack position and connector orientation before inserting the DS200LRPAG1A module.\u003c\/li\u003e\n\u003cli\u003eDisconnect field power sources before removing or installing relay interface boards.\u003c\/li\u003e\n\u003cli\u003eConfirm ribbon cable header connections are fully seated and mechanically secured.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between low-level control wiring and high-voltage field wiring to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate grounding methods for the control rack and panel enclosure.\u003c\/li\u003e\n\u003cli\u003eInspect relay contact wiring for correct polarity, load type, and external protection requirements before energizing the system.\u003c\/li\u003e\n\u003cli\u003eConfirm LED indication behavior after installation through controlled functional testing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44484861263960,"sku":"DS200LRPAG1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200LDCCH1A1_1a2298f6-c749-4e50-88d2-e9954cebb200.jpg?v=1785490181","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-ds200lrpag1a-mark-v-relay-output-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}