{"product_id":"ge-ds200imcpg1cca-i-o-motor-control-processor-board","title":"GE DS200IMCPG1CCA I\/O Motor Control Processor Board","description":"\u003ch2\u003eGE DS200IMCPG1CCA I\/O Motor Control Processor Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200IMCPG1CCA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200IMCPG1CCA\u003c\/strong\u003e I\/O Motor Control Processor Board, operates as a dedicated hardware component for motor control execution, I\/O signal processing, and subsystem communication within the GE Mark V Speedtronic turbine control system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200IMCPG1CCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Motor Control Processor Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V Speedtronic turbine control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e+5 VDC, +\/-15 VDC via backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Configuration\u003c\/td\u003e\n\u003ctd\u003eMotor Control Processor (MCP) and Co-Motor Processor (CMP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003ePROM firmware storage and EEPROM configuration storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eMark V rack edge connectors and multi-pin I\/O connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators, RESET button, built-in test points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Control and Communication Processing\u003c\/h3\u003e\n\u003cp\u003eThe DS200IMCPG1CCA integrates processor resources for execution of motor control routines, analog and digital I\/O signal handling, and communication exchange with other Mark V control boards. The board receives power through the rack backplane and uses onboard firmware storage for control logic configuration.\u003c\/p\u003e\n\u003cp\u003eThe GE industrial control architecture uses defined backplane communication paths for board-to-board data exchange. The IMCP module supports I\/O density scaling through dedicated processor handling of motor-related signals and subsystem communication tasks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power interface does the DS200IMCPG1CCA use?\u003cbr\u003eA: The board receives +5 VDC and +\/-15 VDC power through the Mark V rack backplane connection.\u003c\/p\u003e\n\u003cp\u003eQ: What processors are installed on the IMCP board?\u003cbr\u003eA: The DS200IMCPG1CCA contains a Motor Control Processor (MCP) and a Co-Motor Processor (CMP) for control execution and additional processing functions.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic functions are available on this board?\u003cbr\u003eA: The board provides LED status indicators, a RESET button, and built-in test points for troubleshooting processor and communication conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DS200IMCPG1CCA in the designated Mark V rack slot and verify correct backplane alignment before insertion. Confirm that rack power is removed before replacing or servicing the board.\u003c\/p\u003e\n\u003cp\u003eUse appropriate grounding practices for the control cabinet. Maintain separation between low-level signal wiring and high-current power conductors to reduce electrical interference. Verify connector seating, cable routing, and shielding termination before system startup.\u003c\/p\u003e\n\u003cp\u003eFirmware compatibility should be checked against the existing Mark V controller configuration before board replacement or maintenance activity.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44452938285144,"sku":"DS200IMCPG1CCA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200IMCPG1CCA.jpg?v=1784886117","url":"https:\/\/www.industriaxplc.com\/id\/products\/ge-ds200imcpg1cca-i-o-motor-control-processor-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}