{"product_id":"fc-sdo-1624-honeywell-safe-digital-output-module","title":"FC-SDO-1624 Honeywell | Safe Digital Output Module","description":"\u003ch2\u003eHoneywell FC-SDO-1624 Safe Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for safe digital signal execution in Honeywell Safety Manager and Fail-Safe Controller systems, the \u003cstrong\u003eHoneywell FC-SDO-1624\u003c\/strong\u003e (\u003cstrong\u003eSDO-1624\u003c\/strong\u003e Safe Digital Output Module) provides direct electrical switching control for safety-related field devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-SDO-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eSDO-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafe Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ Fail-Safe Controller (FSC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.2 kg to 2.0 kg (depending on chassis configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 200 x 170 x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 5 W without external load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Quantity\u003c\/td\u003e\n\u003ctd\u003e16 digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e10 ms to 25 ms depending on controller configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSafety-rated digital output interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-state Voltage Drop\u003c\/td\u003e\n\u003ctd\u003eLess than 2.0 VDC at rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Diagnostics\u003c\/td\u003e\n\u003ctd\u003eIndividual channel status monitoring and LED indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ FSC rack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coated industrial assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, TÜV, ATEX depending on system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe FC-SDO-1624 provides 16 safety digital output channels for direct actuator control within Honeywell safety systems. Moreover, each channel incorporates diagnostic monitoring functions to detect output circuit abnormalities, field wiring faults, and device status changes.\u003c\/p\u003e\n\u003cp\u003eThe module operates with 24 VDC field circuits and supports channel-level supervision through the Safety Manager controller. In addition, the hardware design supports electrical isolation between internal control logic and external field connections to maintain signal integrity.\u003c\/p\u003e\n\u003cp\u003eThe module does not provide analog measurement functions. Instead, it executes binary output commands generated by the safety controller logic and transfers these commands to connected field devices such as shutdown valves, relays, and protective actuators.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the FC-SDO-1624 support analog signal measurement?\u003cbr\u003eA: No. The FC-SDO-1624 is a digital output module designed for binary actuator control. Analog input and measurement functions require separate Honeywell I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: What field voltage level does the FC-SDO-1624 operate with?\u003cbr\u003eA: The module is designed for 24 VDC safety field circuits with an operating range of 18 to 30 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module detect output channel faults?\u003cbr\u003eA: The module uses channel diagnostics and status monitoring functions to identify abnormal output conditions and provide diagnostic information to the safety controller.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the FC-SDO-1624 only in the specified Honeywell Safety Manager or FSC rack position.\u003c\/li\u003e\n\u003cli\u003eVerify the module addressing and controller configuration before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eRoute 24 VDC safety circuits separately from high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shield termination methods when field devices require shielded cabling.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal wiring polarity before energizing the field circuit.\u003c\/li\u003e\n\u003cli\u003eCheck diagnostic LED indicators after installation to verify normal module operation.\u003c\/li\u003e\n\u003cli\u003eFollow Honeywell system engineering manuals for grounding, cabinet layout, and maintenance procedures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44376264802392,"sku":"FC-SDO-1624","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-SDO-1624-3.jpg?v=1784015815","url":"https:\/\/www.industriaxplc.com\/id\/products\/fc-sdo-1624-honeywell-safe-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}