{"product_id":"do818-3bse069053r1-abb-advant-ac800m-digital-output-module","title":"DO818 3BSE069053R1 ABB Advant AC800M Digital Output Module","description":"\u003ch2\u003eABB DO818 3BSE069053R1 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC transistor output execution in the ABB S800 I\/O system, the \u003cstrong\u003eABB DO818 3BSE069053R1\u003c\/strong\u003e (\u003cstrong\u003eDO818\u003c\/strong\u003e Digital Output Module) provides direct physical and electrical control of field devices through 32 current sourcing output channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO818 3BSE069053R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e24 VDC (12 - 32 VDC), 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sourcing, current limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Group Isolation\u003c\/td\u003e\n\u003ctd\u003eTwo isolated groups of 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.32 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 2.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +5 V ModuleBus\u003c\/td\u003e\n\u003ctd\u003eTypical 70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V ModuleBus\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V External\u003c\/td\u003e\n\u003ctd\u003e40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 x 11 x 11.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Output Architecture\u003c\/h3\u003e\n\u003cp\u003eThe DO818 3BSE069053R1 integrates into the ABB S800 I\/O architecture through ModuleBus communication and provides high-density digital output control. Each output channel uses a high-side driver with short-circuit protection, over-temperature protection, EMC protection components, inductive load suppression, and optical isolation from the ModuleBus.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module divides the 32 outputs into two individually isolated groups of 16 channels. Each group includes a process voltage supervision input to monitor external field supply conditions. The output drivers provide current limiting functions for connected DC loads and maintain controlled switching behavior during field operation.\u003c\/p\u003e\n\u003cp\u003eThe ABB S800 platform supports I\/O density scaling through modular backplane communication. Therefore, the DO818 enables compact installation for distributed control configurations requiring multiple 24 VDC switching points.\u003c\/p\u003e\n\u003ch3\u003eFirmware and ModuleBus Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe DO818 uses ABB S800 I\/O ModuleBus communication for data exchange with the controller system. The module transfers output status information and diagnostic signals through the ModuleBus interface.\u003c\/p\u003e\n\u003cp\u003eIn addition, the S800 I\/O family provides firmware flash compatibility management through the engineering configuration environment. The DO818 configuration must match the installed controller and I\/O system revision requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many output channels does the ABB DO818 3BSE069053R1 provide?\u003cbr\u003eA: The DO818 provides 32 digital output channels arranged as two isolated groups of 16 channels.\u003c\/p\u003e\n\u003cp\u003eQ: What output protection functions are included in the DO818 module?\u003cbr\u003eA: Each output channel includes short-circuit protection, over-temperature protection, current limiting, EMC protection, and inductive load suppression.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DO818 require an external 24 VDC field supply?\u003cbr\u003eA: Yes. The module uses an external 24 VDC process supply for field outputs, with a typical external current consumption of 40 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DO818 module on the ABB S800 I\/O carrier according to the approved system installation procedure.\u003c\/li\u003e\n\u003cli\u003eVerify that the ModuleBus connection is correctly seated before applying system power.\u003c\/li\u003e\n\u003cli\u003eConfirm field wiring polarity before connecting 24 VDC output devices.\u003c\/li\u003e\n\u003cli\u003eSeparate output wiring from high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding standard where shielded field cables are used.\u003c\/li\u003e\n\u003cli\u003eCheck output load ratings before energizing connected actuators, relays, or DC devices.\u003c\/li\u003e\n\u003cli\u003eVerify process voltage supervision signals before placing the module into normal operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619442028632,"sku":"DO818 3BSE069053R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO818-3BSE069053R1-3_1200x1200_9e6c22f2-96d2-4b73-865a-3dae4ef05265.jpg?v=1787039131","url":"https:\/\/www.industriaxplc.com\/id\/products\/do818-3bse069053r1-abb-advant-ac800m-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}