{"product_id":"do814-3bur001455r1-abb-advant-s800-i-o-digital-output-module","title":"DO814 3BUR001455R1 ABB Advant S800 I\/O Digital Output Module","description":"\u003ch2\u003eABB DO814 3BUR001455R1 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC current sinking output execution in the ABB S800 I\/O system, the \u003cstrong\u003eABB DO814 3BUR001455R1\u003c\/strong\u003e (\u003cstrong\u003eDO814\u003c\/strong\u003e Digital Output Module) provides direct physical signal control through 16 output channels with current limiting protection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO814 3BUR001455R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 x 5.1 x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e24 VDC (12-32 VDC), 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking, current limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O System\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanics\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA at +5 V ModuleBus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Backplane and I\/O Density Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe DO814 operates as an ABB S800 I\/O digital output device with 16 current sinking channels. The module receives control commands through the ModuleBus interface and transfers discrete output signals to connected field devices.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the S800 I\/O architecture supports I\/O density scaling through modular channel allocation. The DO814 provides compact digital output expansion for systems requiring multiple 24 VDC discrete actuators, solenoids, and control circuits.\u003c\/p\u003e\n\u003cp\u003eThe module uses current limiting output technology to control load current and protect output channels against abnormal electrical conditions. Therefore, field wiring design must consider load characteristics and cable routing requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What output signal type does the ABB DO814 3BUR001455R1 provide?\u003cbr\u003eA: The DO814 provides 16 digital output channels using 24 VDC current sinking signals with current limiting functionality.\u003c\/p\u003e\n\u003cp\u003eQ: What ABB platform supports the DO814 module?\u003cbr\u003eA: The DO814 is designed for the ABB S800 I\/O system and uses the S800 mechanical configuration with ModuleBus communication.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental conditions are specified for DO814 operation?\u003cbr\u003eA: The module operates from 0 to +55 deg C and supports 5 to 95 % relative humidity without condensation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DO814 module on the ABB S800 I\/O mounting arrangement according to system hardware documentation.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 VDC field supply polarity before connecting output loads.\u003c\/li\u003e\n\u003cli\u003eSeparate digital output wiring from high voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate grounding methods for cabinet shielding and signal reference connections.\u003c\/li\u003e\n\u003cli\u003eConfirm connected field devices match the module output current limitation and voltage range.\u003c\/li\u003e\n\u003cli\u003eCheck ModuleBus connection integrity before system commissioning.\u003c\/li\u003e\n\u003cli\u003eVerify output channel status indicators after completing field wiring tests.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619469488216,"sku":"DO814 3BUR001455R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO814-3BUR001455R1-3_1200x1200_6583047f-06af-44a4-8ef6-03798e5a33a7.jpg?v=1787039368","url":"https:\/\/www.industriaxplc.com\/id\/products\/do814-3bur001455r1-abb-advant-s800-i-o-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}