{"product_id":"digital-output-module-yokogawa-f3yd08-6a","title":"Digital Output Module | Yokogawa F3YD08-6A","description":"\u003ch2\u003eYokogawa F3YD08-6A Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3YD08-6A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3YD08\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for DC load switching within the FA-M3 Range-free Multi-controller platform. The module provides 8 sink-type transistor output channels for direct electrical actuation of field devices, with isolated output circuitry and removable terminal block wiring.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies a single catalog model: \u003cstrong\u003eF3YD08-6A\u003c\/strong\u003e. No official suffix decomposition or variant matrix is specified in the provided technical data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3YD08-6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Technology\u003c\/td\u003e\n\u003ctd\u003eTransistor Output (Sink Type, Open Collector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e12 VDC to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e4 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Module Current\u003c\/td\u003e\n\u003ctd\u003e12 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (OFF to ON)\u003c\/td\u003e\n\u003ctd\u003e1 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (ON to OFF)\u003c\/td\u003e\n\u003ctd\u003e1 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 VAC between output terminals and internal circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block (M3 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 140 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and DCS Field Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe F3YD08-6A incorporates electrical isolation between output circuits and internal controller electronics. This arrangement reduces the transfer of field-side electrical disturbances into the FA-M3 control backplane. The transistor sink outputs are intended for DC-powered loads connected between the positive supply rail and the corresponding output terminal.\u003c\/p\u003e\n\u003cp\u003eWithin distributed control and process automation environments, isolated digital output modules are commonly deployed alongside analog signal interfaces, including 4-20 mA instrumentation loops and network-connected field devices. The module itself functions as a discrete switching interface and does not provide HART, FOUNDATION Fieldbus, or Profibus PA communication functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the F3YD08-6A support AC output loads?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The specified output operating range is 12 VDC to 24 VDC using sink-type transistor outputs. Load compatibility should be verified against the DC output characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can field wiring be removed without disconnecting individual conductors?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The module uses a removable terminal block design with M3 screw terminals, allowing the terminal assembly to be detached during maintenance procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What current limitation must be considered during output loading?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Both per-channel and aggregate module ratings must be observed. The specified limits are 4 A per output point and 12 A total across the module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify field supply voltage remains within the specified 12 VDC to 24 VDC operating range.\u003c\/li\u003e\n\u003cli\u003eFor sink-type transistor outputs, connect the load between the positive DC supply and the designated output terminal.\u003c\/li\u003e\n\u003cli\u003eConfirm that the combined output current does not exceed the module-level current rating.\u003c\/li\u003e\n\u003cli\u003eRoute output wiring separately from high-energy power conductors where practical to minimize induced electrical noise.\u003c\/li\u003e\n\u003cli\u003eTighten M3 terminal connections according to site electrical standards and periodically inspect for loosening caused by vibration.\u003c\/li\u003e\n\u003cli\u003eEnsure protective grounding and cabinet bonding practices comply with plant electrical installation requirements.\u003c\/li\u003e\n\u003cli\u003eRemove system power before inserting or removing the module unless explicit hot-swap approval is documented by the controller manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44182028746840,"sku":"F3YD08-6A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3YD08-6A-3.jpg?v=1780535174","url":"https:\/\/www.industriaxplc.com\/id\/products\/digital-output-module-yokogawa-f3yd08-6a","provider":"IndustriaX Limited","version":"1.0","type":"link"}