{"product_id":"digital-output-module-abb-s800-i-o-do828-3bse069055r2","title":"Digital Output Module ABB S800 I\/O DO828 3BSE069055R2","description":"\u003ch2\u003eABB DO828 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BSE069055R1 DO828\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDO828\u003c\/strong\u003e Digital Output Module, provides relay-based switching execution for 125 VDC and 250 VAC field circuits within the ABB S800 I\/O system. The module contains 16 individually isolated relay output channels with optical isolation, relay drivers, status indication, and EMC protection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO828\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE069055R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eRelay Output, Normally Open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e5 to 125 VDC \/ 5 to 250 VAC, maximum 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eMaximum 125 VDC \/ 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channel-to-channel and circuit common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTU Compatibility\u003c\/td\u003e\n\u003ctd\u003eTU851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm width x 102 mm depth x 119 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 VDC: 45 mA; +24 VDC: 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal +24 VDC Consumption\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4 and EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Relay Output Architecture\u003c\/h3\u003e\n\u003cp\u003eThe DO828 uses the ABB S800 I\/O backplane communication structure for module control and diagnostics. Each output channel contains an optical isolation barrier, relay driver stage, relay switching element, output LED indication, and EMC protection components.\u003c\/p\u003e\n\u003cp\u003eThe module supports industrial control circuits requiring isolated relay contacts. Additionally, the relay supply voltage supervision monitors the 12 V distribution from the ModuleBus. If the relay supply disappears, the module generates an error signal and activates the Warning LED. The supervision function can be enabled or disabled through configuration parameters.\u003c\/p\u003e\n\u003cp\u003eThe S800 I\/O platform provides modular I\/O density scaling through distributed ModuleBus communication. Therefore, the DO828 integrates directly with ABB controller systems using standardized I\/O addressing and diagnostic handling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB DO828 provide channel-to-channel isolation?\u003cbr\u003eA: Yes. Each of the 16 relay output channels provides individual isolation between channels and the circuit common.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DO828 require an external 24 VDC field supply?\u003cbr\u003eA: No. The module specifies 0 mA external +24 VDC consumption. Relay supply monitoring uses the 12 V distribution available through the ModuleBus.\u003c\/p\u003e\n\u003cp\u003eQ: Which ABB Module Termination Unit is compatible with the DO828?\u003cbr\u003eA: The DO828 is designed for use with the ABB TU851 Module Termination Unit and uses the ED keying code.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DO828 module on the ABB S800 I\/O mounting arrangement with the specified TU851 Module Termination Unit. Verify that the module keying code matches the installed MTU before commissioning.\u003c\/p\u003e\n\u003cp\u003eConnect relay output field wiring according to the specified voltage and current limits. Maintain separation between relay output wiring and sensitive signal cables to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eConfirm protective grounding, cabinet bonding, and EMC installation practices before applying field power. Check front LED indicators after startup to verify module operation, channel status, and relay supply supervision status.\u003c\/p\u003e\n\u003cp\u003eEnsure ambient temperature, humidity, pollution degree, and enclosure conditions remain within the specified operating limits.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44619255939160,"sku":"DO828 3BSE069055R2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DO8283BSE069055R2-3.jpg?v=1787038369","url":"https:\/\/www.industriaxplc.com\/id\/products\/digital-output-module-abb-s800-i-o-do828-3bse069055r2","provider":"IndustriaX Limited","version":"1.0","type":"link"}