{"product_id":"devicenet-communication-boards-abb-dsqc658-3hac025779-001","title":"DeviceNet Communication Boards ABB DSQC658 3HAC025779-001","description":"\u003ch2\u003eABB DSQC658 DeviceNet M\/S Single\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DSQC658 3HAC025779-001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDSQC658\u003c\/strong\u003e DeviceNet communication board, provides DeviceNet master\/slave communication within ABB IRC5 controllers. It exchanges control and status data with connected DeviceNet nodes through the controller network interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSQC658\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3HAC025779-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Communication Board, Master\/Slave Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controller\u003c\/td\u003e\n\u003ctd\u003eABB IRC5 Robot Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eDeviceNet, CAN-based fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Baud Rates\u003c\/td\u003e\n\u003ctd\u003e125 kbps, 250 kbps, 500 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.08 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEstimated shipping size: 2 x 8.7 x 12.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eInternal board installation in IRC5 controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Indicators\u003c\/td\u003e\n\u003ctd\u003ePower, module status, network status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Function\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Master\/Slave, single interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Industrial Network and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe DSQC658 provides a DeviceNet interface for exchanging cyclic and diagnostic data between the IRC5 controller and external nodes. Therefore, the board supports bus-based I\/O communication instead of point-to-point discrete wiring.\u003c\/p\u003e\n\u003cp\u003eDeviceNet uses CAN-based communication, while the available baud rates provide selectable network operating speeds. The installation must match the configured network baud rate and node settings.\u003c\/p\u003e\n\u003cp\u003eIn addition, the board uses status indicators to assist with power, module, and network diagnostics. Technicians can therefore identify basic communication conditions directly at the controller hardware.\u003c\/p\u003e\n\u003cp\u003eThe supplied data identifies the DSQC658 as a single Master\/Slave DeviceNet interface. It does not specify redundant DeviceNet operation, hot-swap capability, or a defined backplane current load.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the DSQC658 operate as both a DeviceNet Master and Slave?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The supplied product designation identifies the unit as a DeviceNet Master\/Slave Single interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What DeviceNet communication speeds does the DSQC658 support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specifications list 125 kbps, 250 kbps, and 500 kbps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the supplied data confirm hot-swap operation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The supplied documentation does not specify hot-swap support. Treat the board as an internal controller component and follow the applicable IRC5 service procedure before removal or installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate controller power before installing or removing the internal communication board.\u003c\/li\u003e\n\u003cli\u003eVerify the DSQC658 part number, board identification, and controller compatibility before installation.\u003c\/li\u003e\n\u003cli\u003eRoute DeviceNet cabling separately from high-current motor and power wiring where practical.\u003c\/li\u003e\n\u003cli\u003eMaintain the DeviceNet cable shield and termination arrangement specified by the network design.\u003c\/li\u003e\n\u003cli\u003eVerify node addressing, baud rate, and network configuration before placing the controller into normal operation.\u003c\/li\u003e\n\u003cli\u003eInspect connectors for correct seating and mechanical retention before energizing the controller.\u003c\/li\u003e\n\u003cli\u003eUse the front-panel diagnostic LEDs to check module and network status after startup.\u003c\/li\u003e\n\u003cli\u003eDo not assume hot-swap capability unless the applicable ABB IRC5 hardware documentation explicitly permits it.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44685577584728,"sku":"DSQC658 3HAC025779-001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DSQC658-3HAC025779-001-3_1200x1200_48077a47-8251-4537-9923-bfcb46af29f9.jpg?v=1788157405","url":"https:\/\/www.industriaxplc.com\/id\/products\/devicenet-communication-boards-abb-dsqc658-3hac025779-001","provider":"IndustriaX Limited","version":"1.0","type":"link"}