{"product_id":"ci868ak01-3bse092691r1-abb-iec-61850-communication-interfaces","title":"CI868AK01 3BSE092691R1 ABB IEC 61850 Communication Interfaces","description":"\u003ch2\u003eABB CI868A IEC 61850 Interface\u003c\/h2\u003e\n\u003cp\u003eConfigured for IEC 61850 communication in System 800xA, the \u003cstrong\u003eABB CI868A\u003c\/strong\u003e (\u003cstrong\u003eCI868\u003c\/strong\u003e IEC 61850 Interface) connects an AC 800M controller with external Ethernet devices. It supports MMS client communication and GOOSE publishing\/subscription, with 10\/100 Mbit\/s Ethernet connectivity through the TP868 Baseplate.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI868A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eCI868\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIEC 61850 Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE092691R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eSystem 800xA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eIEC 61850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC 61850 Edition\u003c\/td\u003e\n\u003ctd\u003eEdition 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClient \/ Server Functions\u003c\/td\u003e\n\u003ctd\u003eMMS Client, GOOSE Publisher and Subscriber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connector\u003c\/td\u003e\n\u003ctd\u003eRJ-45 female, 8-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 RJ-45 connectors on TP868 Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCH1 Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEX-Bus Capacity\u003c\/td\u003e\n\u003ctd\u003eMaximum 12 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e3.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed with HI Controller\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eG3, ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20, EN 60529 \/ IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eUL 61010-1, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eUL 60079-15, cULus Class 1, Zone 2, AEx nA IIC T4, Ex nA IIC T4Gc X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certifications\u003c\/td\u003e\n\u003ctd\u003eDNV-GL; ABS, BV and LR pending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, Including Base\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible System Versions\u003c\/td\u003e\n\u003ctd\u003eSystem 800xA 6.0.3.3, 6.1.1 and subsequent versions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIEC 61850 Communication and Ethernet Interface\u003c\/h3\u003e\n\u003cp\u003eThe CI868A provides an Ethernet communication path between an AC 800M controller and IEC 61850 external devices. It implements IEC 61850 Edition 2 functions for substation automation data exchange.\u003c\/p\u003e\n\u003cp\u003eThe module supports MMS as a client and GOOSE as both publisher and subscriber. Therefore, the controller can exchange IEC 61850 process and control data without requiring a separate controller for the electrical control interface.\u003c\/p\u003e\n\u003cp\u003eThe TP868 Baseplate provides two RJ-45 Ethernet connectors. CH1 supports 10 Mbit\/s or 100 Mbit\/s operation. The Ethernet connection must pass through an Ethernet switch before connecting to the main network.\u003c\/p\u003e\n\u003cp\u003eThe baseplate uses a mechanical code lock to prevent installation of an incompatible unit type. This coding mechanism restricts incorrect module installation on the corresponding baseplate.\u003c\/p\u003e\n\u003ch3\u003eCEX-Bus and Power Architecture\u003c\/h3\u003e\n\u003cp\u003eThe CI868A expansion unit contains the CEX-Bus logic, communication electronics, and a DC\/DC converter. The converter derives the required internal voltages from the +24 V supply through the CEX-Bus.\u003c\/p\u003e\n\u003cp\u003eThe CEX-Bus supports up to 12 units. Typical 24 V consumption is 160 mA, while the specified power dissipation is 3.8 W.\u003c\/p\u003e\n\u003cp\u003eABB specifies hot-swap capability for the module. However, network configuration, controller state, and system maintenance procedures should be considered before removing or installing the unit in an operating system.\u003c\/p\u003e\n\u003cp\u003eThe CI868A does not provide network redundancy or module redundancy according to the supplied technical data.\u003c\/p\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe CI868A is specified for System 800xA version 6.0.3.3, version 6.1.1, and subsequent versions. System software compatibility should therefore be verified before deployment or replacement.\u003c\/p\u003e\n\u003cp\u003eThe module can also be used together with an HI Controller where the corresponding System 800xA configuration supports the hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What IEC 61850 communication functions does the CI868A provide?\u003c\/strong\u003e\u003cbr\u003eA: The CI868A supports MMS client communication and GOOSE publishing and subscription under IEC 61850 Edition 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What Ethernet speed does the CI868A support?\u003c\/strong\u003e\u003cbr\u003eA: The TP868 Baseplate CH1 Ethernet interface supports 10 Mbit\/s and 100 Mbit\/s operation through an RJ-45 connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CI868A support network or module redundancy?\u003c\/strong\u003e\u003cbr\u003eA: The supplied specifications state that both network redundancy and module redundancy are not supported.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CI868A only on the compatible TP868 Baseplate and verify the mechanical code before insertion.\u003c\/li\u003e\n\u003cli\u003eConnect the Ethernet cable through an appropriate Ethernet switch before connecting to the main network.\u003c\/li\u003e\n\u003cli\u003eUse the designated CH1 RJ-45 connector for the specified Ethernet communication path.\u003c\/li\u003e\n\u003cli\u003eMaintain physical separation between Ethernet communication cables and high-voltage or high-current conductors where practical.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables to minimize exposure to electromagnetic interference from switching equipment and power circuits.\u003c\/li\u003e\n\u003cli\u003eVerify the +24 V supply and CEX-Bus installation before commissioning the communication interface.\u003c\/li\u003e\n\u003cli\u003eConfirm that the installed System 800xA version is 6.0.3.3, 6.1.1, or a subsequent supported version.\u003c\/li\u003e\n\u003cli\u003eCheck IEC 61850 device configuration, MMS client parameters, and GOOSE publisher\/subscriber assignments before placing the controller into service.\u003c\/li\u003e\n\u003cli\u003eObserve the specified 0 to +55 deg C operating temperature range and 5 to 95 % non-condensing relative humidity range.\u003c\/li\u003e\n\u003cli\u003eProvide an enclosure or installation environment that maintains the specified IP20 protection and pollution conditions.\u003c\/li\u003e\n\u003cli\u003eFollow the applicable IEC\/EN, UL, hazardous-location, and site-specific electrical installation requirements during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623558312024,"sku":"CI868AK01 3BSE092691R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI868AK01-3BSE092691R1-3_1200x1200_9183c8dc-0217-4073-91ac-0617135693af.jpg?v=1787126849","url":"https:\/\/www.industriaxplc.com\/id\/products\/ci868ak01-3bse092691r1-abb-iec-61850-communication-interfaces","provider":"IndustriaX Limited","version":"1.0","type":"link"}