{"product_id":"ci856-3bse026055r1-abb-s100-i-o-communication-interface","title":"CI856 3BSE026055R1 ABB S100 I\/O Communication Interface","description":"\u003ch2\u003eABB CI856K01 S100 I\/O Communication Interface\u003c\/h2\u003e\n\u003cp\u003eConfigured for S100 I\/O communication in AC 800M systems, the \u003cstrong\u003eABB CI856K01\u003c\/strong\u003e (\u003cstrong\u003eCI856\u003c\/strong\u003e S100 I\/O Communication Interface) provides the communication path between the AC 800M controller and S100 I\/O racks. The CI856 connects to the CEX-Bus through the TP856 baseplate and requires no separate external power source.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI856K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eCI856\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE026055R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eS100 I\/O Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eABB S100 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Interface\u003c\/td\u003e\n\u003ctd\u003eCEX-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster or Slave\u003c\/td\u003e\n\u003ctd\u003eMaster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHI Controller Compatibility\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Units on CEX-Bus\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS100 I\/O Rack Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 5 racks per CI856\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Boards per Rack\u003c\/td\u003e\n\u003ctd\u003eUp to 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e36-pin Miniribbon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003ctd\u003eTP856\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eAC 800M processor unit via CEX-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC Consumption\u003c\/td\u003e\n\u003ctd\u003eTyp. 120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 2.88 W at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eG3 compliant to ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN 60529 and IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Including Base\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCEX-Bus and S100 I\/O Communication\u003c\/h3\u003e\n\u003cp\u003eThe CI856 exchanges S100 I\/O data with the AC 800M controller through the CEX-Bus interface. The TP856 baseplate provides the mechanical mounting interface and houses the ribbon connector used for connection to S100 I\/O rack bus extender boards.\u003c\/p\u003e\n\u003cp\u003eOne CI856 can connect to up to five S100 I\/O racks. Each rack can accommodate up to 20 I\/O boards. Therefore, the supported architecture permits distributed S100 I\/O expansion while retaining the controller-side CEX-Bus connection.\u003c\/p\u003e\n\u003cp\u003eThe module receives its operating power from the AC 800M processor unit through the CEX-Bus. Consequently, the CI856 does not require a separate external power supply.\u003c\/p\u003e\n\u003cp\u003eThe specified 36-pin Miniribbon connector provides the physical interface for the communication assembly. The TP856 baseplate also supports DIN-rail mounting for installation within the control cabinet.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many S100 I\/O racks can one CI856K01 support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e One CI856K01 can connect to up to five S100 I\/O racks, with each rack supporting up to 20 I\/O boards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CI856K01 require an external power supply?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The CI856 receives power from the AC 800M processor unit through the CEX-Bus. Its typical 24 VDC consumption is 120 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What connector does the CI856K01 use for the CEX-Bus connection?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specification identifies a 36-pin Miniribbon connector. The connector is housed through the TP856 baseplate assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the TP856 baseplate on a suitable DIN rail inside the control cabinet.\u003c\/li\u003e\n\u003cli\u003eInstall the CI856 communication interface on the TP856 baseplate according to the AC 800M hardware installation procedure.\u003c\/li\u003e\n\u003cli\u003eConnect the baseplate to the CEX-Bus using the specified system connection arrangement.\u003c\/li\u003e\n\u003cli\u003eConnect the TP856 ribbon interface to the S100 I\/O rack bus extender boards.\u003c\/li\u003e\n\u003cli\u003eRoute communication and power-related wiring separately from high-current switching and high-noise circuits where practical.\u003c\/li\u003e\n\u003cli\u003eVerify connector seating and mechanical retention before energizing the controller assembly.\u003c\/li\u003e\n\u003cli\u003eMaintain cabinet grounding and shielding practices specified by the AC 800M and S100 I\/O installation documentation.\u003c\/li\u003e\n\u003cli\u003eConfirm that the installed rack count and I\/O board count remain within the CI856 architecture limits.\u003c\/li\u003e\n\u003cli\u003eCheck the cabinet operating temperature against the specified 0 to +55 deg C range.\u003c\/li\u003e\n\u003cli\u003eInspect the installation for correct IP20 enclosure protection and adequate environmental control.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623593570392,"sku":"CI856 3BSE026055R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI856K01-3BSE026055R1-3_1200x1200_caf6d797-855a-464d-b136-0fab2d8a9c2d.jpg?v=1787127875","url":"https:\/\/www.industriaxplc.com\/id\/products\/ci856-3bse026055r1-abb-s100-i-o-communication-interface","provider":"IndustriaX Limited","version":"1.0","type":"link"}