{"product_id":"ci850ak01-3bse026055r1-abb-ac-800m-interface-kit","title":"CI850AK01 3BSE026055R1 ABB AC 800M Interface Kit","description":"\u003ch2\u003eABB CI856K01 S100 I\/O Interface Kit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB CI856K01 3BSE026055R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI856K01\u003c\/strong\u003e S100 I\/O Interface Kit, provides physical communication between the AC 800M controller and an S100 I\/O system through the CEX-Bus. The kit includes the CI856 Communication Interface and TP856 Baseplate.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI856K01 3BSE026055R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSE026055R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eS100 I\/O Interface Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eCommunication between AC 800M and S100 system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Components\u003c\/td\u003e\n\u003ctd\u003eCI856 Communication Interface, TP856 Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Units on CEX-Bus\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniribbon, 36-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN 60529, IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Shipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e18.7 x 6.5 x 13 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAC 800M and S100 I\/O Communication\u003c\/h3\u003e\n\u003cp\u003eThe CI856 provides the communication interface required between an AC 800M controller and an S100 I\/O system. The interface connects through the CEX-Bus, while the TP856 baseplate provides the physical mounting and connection structure.\u003c\/p\u003e\n\u003cp\u003eThe configuration supports up to 12 units on the CEX-Bus. In addition, the interface uses a 36-pin Miniribbon connector for connection to the S100 I\/O side. The specified typical consumption is 120 mA at 24 V.\u003c\/p\u003e\n\u003cp\u003eThe TP856 baseplate forms part of the complete CI856K01 kit. Therefore, installation should treat the communication interface and baseplate as the supplied hardware assembly.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What components are included with CI856K01 3BSE026055R1?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The kit includes one CI856 Communication Interface and one TP856 Baseplate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many units can the CI856 support on the CEX-Bus?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified maximum is 12 units on the CEX-Bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What connector does the CI856K01 use?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The interface uses a 36-pin Miniribbon connector for the specified S100 I\/O connection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the TP856 baseplate securely according to the AC 800M installation arrangement.\u003c\/li\u003e\n\u003cli\u003eInstall the CI856 communication interface onto the baseplate and verify proper mechanical engagement.\u003c\/li\u003e\n\u003cli\u003eConnect the CEX-Bus wiring according to the controller system configuration.\u003c\/li\u003e\n\u003cli\u003eConnect the 36-pin Miniribbon interface using the specified mating connector and avoid excessive cable bending.\u003c\/li\u003e\n\u003cli\u003eRoute communication wiring separately from high-voltage and high-current conductors where practical.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 V supply and confirm that the connected load remains within the specified current requirement.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified IP20 environmental protection conditions during cabinet installation.\u003c\/li\u003e\n\u003cli\u003eBefore energizing the system, inspect connectors, mounting points, cable routing, and grounding connections.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623684927576,"sku":"CI850AK01 3BSE026055R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI850AK013BSE026055R1-3.jpg?v=1787129478","url":"https:\/\/www.industriaxplc.com\/id\/products\/ci850ak01-3bse026055r1-abb-ac-800m-interface-kit","provider":"IndustriaX Limited","version":"1.0","type":"link"}