{"product_id":"cc-udir01-digital-input-relay-adapter-honeywell","title":"CC-UDIR01 Digital Input Relay Adapter | Honeywell","description":"\u003ch2\u003eHoneywell CC-UDIR01 Digital Input Relay Adapter\u003c\/h2\u003e\n\u003cp\u003eConfigured for digital signal relay interfacing in the Honeywell Universal Marshalling Solution (EP-SCA-100), the \u003cstrong\u003eHoneywell CC-UDIR01\u003c\/strong\u003e (\u003cstrong\u003eCC-UDIR01\u003c\/strong\u003e Digital Input Relay Adapter) provides direct physical\/electrical execution between field devices and DCS input logic circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-UDIR01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e118 mm depth x 85.5 mm width x 10.0 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSingle-channel Digital Input Relay Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eUniversal Marshalling Solution (EP-SCA-100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Input Current\u003c\/td\u003e\n\u003ctd\u003e8.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003eSPDT relay with COM and NO terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eAgSnO2, gold-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Current\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Switching Current\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease Time\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil-to-Contact Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eBackplane mount via CC-USCA01 Signal Conditioning Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlammability Rating\u003c\/td\u003e\n\u003ctd\u003eUL 94 V0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and DCS Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CC-UDIR01 uses an electromechanical relay interface to provide galvanic isolation between field wiring and control system circuits. The coil side accepts a 24 VDC field signal, while the relay contact side provides isolated switching through COM and NO connections for DCS logic processing.\u003c\/p\u003e\n\u003cp\u003eThe module is designed for installation within the Honeywell Universal Marshalling Solution architecture. Mechanical keying prevents incorrect module insertion, and the integrated green LED provides local indication of coil activation status.\u003c\/p\u003e\n\u003cp\u003eFor process control signal architectures, the module supports channel-to-channel isolation practices commonly applied in DCS marshalling environments. Signal separation, field wiring segregation, and grounding methods should follow the applicable Honeywell system installation requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-UDIR01 require an external power supply?\u003cbr\u003eA: No. The module operates from the 24 VDC field signal applied to the relay coil input. No separate external module power connection is specified.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CC-UDIR01 be installed directly on a DIN rail?\u003cbr\u003eA: The module is installed through the CC-USCA01 Signal Conditioning Assembly backplane. The mounting method is a backplane-based installation rather than direct standalone DIN rail mounting.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation function is provided by the relay adapter?\u003cbr\u003eA: The module provides coil-to-contact electrical isolation rated at 1500 VAC RMS, separating field signal circuits from DCS contact interfaces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CC-UDIR01 only in the designated Universal Marshalling Solution backplane position.\u003c\/li\u003e\n\u003cli\u003eVerify mechanical keying alignment before insertion to prevent incorrect module placement.\u003c\/li\u003e\n\u003cli\u003eRoute field signal wiring separately from high-voltage power conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eApply appropriate shield termination and grounding practices according to the control system installation standard.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal identification for coil input and relay contact connections before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003eInspect LED status indication after installation to verify relay coil activation behavior.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44345363103832,"sku":"CC-UDIR01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-UDIR01-3.jpg?v=1783489634","url":"https:\/\/www.industriaxplc.com\/id\/products\/cc-udir01-digital-input-relay-adapter-honeywell","provider":"IndustriaX Limited","version":"1.0","type":"link"}